background image

User’s manual · TFF 310 CI 

 

         

- 2 -                TFF 310 CI                 version_en_2.0               FTE maximal 

 

1.3.

 

Description and connections 

The module TFF 310 CI is used for the reception of free channels that obey the DVB-T standards.  
Each module allows the reception of a complete multiplex in DVB-T (COFDM), and its subsequent regeneration in a new 
multiplex. Besides, it offers the possibility of selecting the services that you wish to add in the new multiplex. 
A feature of this equipment is its modulator in Vestigial Side Band (or VSB). This modulation can be used to distribute 
adjacent channels in one distribution without any interference problem. 
Each module has one Loop connector to cascade several modules at input and a Mix connector to do same in output 
channels

The output channel is selectable between C2 and C69. 

All parameters are programmed by the means of PRO 201, PRO 300 or the EVO or MINI series of field strength meter, 
and they are monitored in the display of programmer or on the screen of field strength meter. 
TFF 310 CI has two Common Interface slots. 
 
 
TFF 310 CI 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 
 
*States of two-colored leds  
1. Initialization mode 

- Green: main application charged.  
- Blinking Green: Completing the initial sequence, at the moment when the module gets initialized, the led will turn 

into one of the states the operating mode.  

- Red: Phase of initializing the module.  

2. Operative Mode  

- Green: The system is working properly.  
- Orange: At least one critical event has been recorded in the module. The led will only change into green when 

the registration of events has been read by the programmer.  

- Red: Error or alert detected in the running of the device, the led will be on only as long as the error/alert is 

present. Once the error or the alert disappears, the led will change into orange because the error/alert is stored in 
the registration of events. 

3. Programming mode  

- When the module detects an external programmer, the led will blink in the next sequence: green-orange-red.  
- Once you leave the programming mode, the led will turn into the corresponding operating mode. 

 

1. Two-colored led*: It indicates the different states of the device.
2. CI: Common Interface. 
3. OUT: This connector supplies the modulated channel according to the 
selected standard in the module and mixes it with all the signals that it 
receives throught the MIX connector 
4. MIX: Input of mixing of the module. 
5. ANT IN: To connect to the antenna or to the LOOP OUT output of the 
previous module 
6. LOOP OUT: To connect to the ANT IN input of the next module. 
7. RS 232: Ethernet connector to cascade modules with the RCM 310 
telecontrol unit with the RJ45/RJ45 cable provided. 
8. PRO 201: Ethernet connector to make the programming with the 
programmer. 
9. DC connectors: It has two connectors for connecting between modules. 

Summary of Contents for TFF 310 CI

Page 1: ...TFF 310 CI USER S MANUAL...

Page 2: ...nges of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to the...

Page 3: ...ting mode Red Phase of initializing the module 2 Operative Mode Green The system is working properly Orange At least one critical event has been recorded in the module The led will only change into gr...

Page 4: ...el and output parameters of a multiplex with a corrected error rate 1 4 Programming TFF 310 CI has two ethernet connectors In order to make the programming of the module you have to connect the corres...

Page 5: ...ols option through the key 8 of your field strength meter and to select the Transmodulator Prog option Then it will proceed to recognize the module and to show the main menu In the Transmodulator Prog...

Page 6: ...f the multiplex that you wish to tune When you modify this field the field Channel will be also modified indicating the channel equivalent to the selected frequency in the case that this frequency cor...

Page 7: ...are indicated the registered events in the module Read log It allows reading the registered events in the module Clear log It allows deleting all events stored until this moment Export log to USB It a...

Page 8: ...ork into the internal disk or in the external storage device USB 2 0 Once the option is selected a dialog box will appear and we will be able to choose among three different options Auto The Meter dec...

Page 9: ...s 1 Select the Service to remove option 2 Select one of the multiplex services you want to remove 3 Once you have chosen the service select the Add Rem button to remove the service in the multiplex Re...

Page 10: ...ured when tuning the standard definition channel it will move to its position in high definition automatically This option allows modifying manually the position of the LCN exchanging the standard pos...

Page 11: ...Ter In this option you will be able to configure the input parameters of the terrestrial signal Freq MHz Input frequency of the multiplex that you wish to tune In order to introduce the frequency pre...

Page 12: ...save the current configuration of the module 3 A window will appear and it will let you know that the reading made has been correct Write to module It loads in the module one of the configurations pre...

Page 13: ...e selected the DVB T DVB H modulator configuration you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services Adding Services 1 Select t...

Page 14: ...rent time and date SW version info It allows you to visualize the basic information of the module model firmware version etc Global Update It allows carrying out the update of all the modules that are...

Page 15: ...nfiguration Output configuration Out TV In these options you can configure the output parameters of the terrestrial signal RF Channel MHz Output frequency of terrestrial modulation In order to introdu...

Page 16: ...OK the edition mode is on placing the cursor over the digit the value could be changed by means the bottoms Up Down One time finished the changes are saved pressing OK LCN The LCN function allows ass...

Page 17: ...ave the registration of errors linked to the current time and date Read LOG file It allows reading the registered events in the module 1 Select the option Read LOG file through Up Down buttons Press O...

Page 18: ...are specified below 1 Select the option Write to module through Up Down buttons Press OK to continue 2 Select the position of the CFG memory that you wish to copy in the module Please verify that the...

Page 19: ...to be removed through Up Down buttons then press OK 3 Select the service you want to delete with the Left Right keys Then press OK over Rem in order to remove it or press OK over All in order to dele...

Page 20: ...MP 310 P C d 2003520 Terrestrial antenna Installation where we get a bad signal and high error rates in the output of the antenna This signal is injected in the headend formed by 6 TFF 310 CI regenera...

Page 21: ...ode DVB T 2k 8k DVB H 2k 4k 8k Output channels C2 C69 Output connectors Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses 1 dB Band spurious 60 dBc Programming Interface RJ 45...

Page 22: ...6 1 32 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 358 4us 179 2us 89 6us 44 8us 179 2us 89 6us 44 8us 22 4us 89 6us 44 8us 22 4us 11 2us Modulation Modulation QPSK 16 QAM 64 QAM Number of bits per s...

Page 23: ...19 353 20 491 21 112 3 4 19 595 21 772 23 053 23 751 5 6 21 772 24 191 25 614 26 39 64 QAM 7 8 22 861 25 401 26 895 27 71 Useful channel capacity 6 MHz Guard Interval Modulation FEC codification 1 4 1...

Page 24: ...90 97 48 info fte it www ftemaximal com DEUTSCHLAND Zweigniederlassung Deutschland F rstenhof 68 59368 Werne Amtsgericht Dortmund HRB 21674 Ust ID Nr DE243384161 Tel 49 2389 92419 0 Fax 49 2389 92419...

Reviews: