Note: It is not recommended to exceed the 85% of the maximum capacity of the multiplex due to the possible 
variability of the bits rate of the inputs services. 
 

 
- Output service name: This option allows editing the services name and changing it. By means the bottoms “Left / Right” 
the service to edit is selected, pressing OK the edition mode is on, placing the cursor over the digit the value could be 
changed by means the bottoms “Up / Down”. Once finish, the changes are saved pressing OK. 
- LCN: The LCN function allows assigning automatically a predetermined 
position to each one of the services of the multiplex. This function will allow the 
users who have a receiver with LCN support to make the ordination of channels 
automatically. 
Select a channel through Left/Right buttons and introduce the position. Press 
the “OK” button and the cursor will be placed over the number. With the keys of 
the cursor, we can move through all the digits and change the values. Press 
“OK” in order to save the changes 
 

Note:  If in the existing installation there are already services that have LCN system, you will have to configure 
the position of the module services in order to avoid conflicts with other net services. 
 

 
- Decrypt services: From this option you can add or remove manually the services that are being decoded by the card: 
 

- Delete services 

 

- Add services 

-Reset CAM: This option allows the CAM initialization, select the slot is necessary  
-CI menu: From this option the access to the CAM menu is allowed, select the slot is necessary.  
- Date / Time: Setting of the date and time of transmodulator. It is appropriate to maintain these parameters set in order to 
have the registration of errors linked to the current time and date.  
- SW version info: It allows you to visualize the basic information of the module: model, firmware version, etc. 
- Global Update: It allows carrying out the update of all the modules that are interconnected at the same time. 
 
PRO 300 
 

Note: From PRO 300 programmer you can only carry out the programming of a single module, in order to carry 
out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX 
MINI series field strength meter. 

 
When you connect the PRO 300 programmer, it will proceed to recognize 
the module and to show the main menu.  
In the main menu are shown the different options for configuring the 
regenerator.  
We have to use the “Up” and “Down” buttons of the keyboard in order to 
move to the different options, and to get into the submenus we have to 
press “OK” button.  
 
 
1. I/O configuration  
Inside the “I/O configuration” menu there are specified the different options 
for setting up the input, output and modulation parameters. 
In order to move around the different options we have to use the “Up” and 
“Down” buttons of the keyboard. Click on OK to edit the selected parameter 
and Right/Left for changing it. Once it is configured press Cancel. 

 
 

Terrestrial input (Input Ter) 
In this option you will be able to configure the input parameters of the 
terrestrial signal:  
 
- Freq. (MHz): Input frequency of the multiplex that you wish to tune. In order 
to introduce the frequency, press the “OK” button and the cursor will be 
placed over the frequency. With the keys of the cursor, we can move through 
all the digits and change the values. Press “OK” in order to save the value. 
Options: 170-230 / 470-862 MHz. 
- BW (Bandwidth): Selection of the input signal Bandwidth: 8MHz, 7MHz and 6MHz. 

Main menu 

1.I/O configuration

_   ___

2.System
3.SD Backup 
4.CAM

TFF 310 CI

I/O configuration 

1.Input Ter

_   ___

2.Out Ter 
3.Out TV 
4.Services config. 

TFF 310 CI

Input ter 

1.Freq              570000 

2.Bandwith           8 MHz 

TFF 310 CI

  TSF 310 

LCN:00004 arte HD

 

 

Summary of Contents for TFF 310 CI

Page 1: ...TFF 310 CI USER S MANUAL...

Page 2: ...nges of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to the...

Page 3: ...ting mode Red Phase of initializing the module 2 Operative Mode Green The system is working properly Orange At least one critical event has been recorded in the module The led will only change into gr...

Page 4: ...el and output parameters of a multiplex with a corrected error rate 1 4 Programming TFF 310 CI has two ethernet connectors In order to make the programming of the module you have to connect the corres...

Page 5: ...ols option through the key 8 of your field strength meter and to select the Transmodulator Prog option Then it will proceed to recognize the module and to show the main menu In the Transmodulator Prog...

Page 6: ...f the multiplex that you wish to tune When you modify this field the field Channel will be also modified indicating the channel equivalent to the selected frequency in the case that this frequency cor...

Page 7: ...are indicated the registered events in the module Read log It allows reading the registered events in the module Clear log It allows deleting all events stored until this moment Export log to USB It a...

Page 8: ...ork into the internal disk or in the external storage device USB 2 0 Once the option is selected a dialog box will appear and we will be able to choose among three different options Auto The Meter dec...

Page 9: ...s 1 Select the Service to remove option 2 Select one of the multiplex services you want to remove 3 Once you have chosen the service select the Add Rem button to remove the service in the multiplex Re...

Page 10: ...ured when tuning the standard definition channel it will move to its position in high definition automatically This option allows modifying manually the position of the LCN exchanging the standard pos...

Page 11: ...Ter In this option you will be able to configure the input parameters of the terrestrial signal Freq MHz Input frequency of the multiplex that you wish to tune In order to introduce the frequency pre...

Page 12: ...save the current configuration of the module 3 A window will appear and it will let you know that the reading made has been correct Write to module It loads in the module one of the configurations pre...

Page 13: ...e selected the DVB T DVB H modulator configuration you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services Adding Services 1 Select t...

Page 14: ...rent time and date SW version info It allows you to visualize the basic information of the module model firmware version etc Global Update It allows carrying out the update of all the modules that are...

Page 15: ...nfiguration Output configuration Out TV In these options you can configure the output parameters of the terrestrial signal RF Channel MHz Output frequency of terrestrial modulation In order to introdu...

Page 16: ...OK the edition mode is on placing the cursor over the digit the value could be changed by means the bottoms Up Down One time finished the changes are saved pressing OK LCN The LCN function allows ass...

Page 17: ...ave the registration of errors linked to the current time and date Read LOG file It allows reading the registered events in the module 1 Select the option Read LOG file through Up Down buttons Press O...

Page 18: ...are specified below 1 Select the option Write to module through Up Down buttons Press OK to continue 2 Select the position of the CFG memory that you wish to copy in the module Please verify that the...

Page 19: ...to be removed through Up Down buttons then press OK 3 Select the service you want to delete with the Left Right keys Then press OK over Rem in order to remove it or press OK over All in order to dele...

Page 20: ...MP 310 P C d 2003520 Terrestrial antenna Installation where we get a bad signal and high error rates in the output of the antenna This signal is injected in the headend formed by 6 TFF 310 CI regenera...

Page 21: ...ode DVB T 2k 8k DVB H 2k 4k 8k Output channels C2 C69 Output connectors Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses 1 dB Band spurious 60 dBc Programming Interface RJ 45...

Page 22: ...6 1 32 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 358 4us 179 2us 89 6us 44 8us 179 2us 89 6us 44 8us 22 4us 89 6us 44 8us 22 4us 11 2us Modulation Modulation QPSK 16 QAM 64 QAM Number of bits per s...

Page 23: ...19 353 20 491 21 112 3 4 19 595 21 772 23 053 23 751 5 6 21 772 24 191 25 614 26 39 64 QAM 7 8 22 861 25 401 26 895 27 71 Useful channel capacity 6 MHz Guard Interval Modulation FEC codification 1 4 1...