User’s manual · TFF 310 CI
- 13 - TFF 310 CI version_en_2.0 FTE maximal
Note: It is not recommended to exceed the 85% of the maximum capacity of the multiplex due to the possible
variability of the bits rate of the inputs services.
- Output service name: This option allows editing the services name and changing it. By means the bottoms “Left / Right”
the service to edit is selected, pressing OK the edition mode is on, placing the cursor over the digit the value could be
changed by means the bottoms “Up / Down”. Once finish, the changes are saved pressing OK.
- LCN: The LCN function allows assigning automatically a predetermined
position to each one of the services of the multiplex. This function will allow the
users who have a receiver with LCN support to make the ordination of channels
automatically.
Select a channel through Left/Right buttons and introduce the position. Press
the “OK” button and the cursor will be placed over the number. With the keys of
the cursor, we can move through all the digits and change the values. Press
“OK” in order to save the changes
Note: If in the existing installation there are already services that have LCN system, you will have to configure
the position of the module services in order to avoid conflicts with other net services.
- Decrypt services: From this option you can add or remove manually the services that are being decoded by the card:
- Delete services
- Add services
-Reset CAM: This option allows the CAM initialization, select the slot is necessary
-CI menu: From this option the access to the CAM menu is allowed, select the slot is necessary.
- Date / Time: Setting of the date and time of transmodulator. It is appropriate to maintain these parameters set in order to
have the registration of errors linked to the current time and date.
- SW version info: It allows you to visualize the basic information of the module: model, firmware version, etc.
- Global Update: It allows carrying out the update of all the modules that are interconnected at the same time.
PRO 300
Note: From PRO 300 programmer you can only carry out the programming of a single module, in order to carry
out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX
MINI series field strength meter.
When you connect the PRO 300 programmer, it will proceed to recognize
the module and to show the main menu.
In the main menu are shown the different options for configuring the
regenerator.
We have to use the “Up” and “Down” buttons of the keyboard in order to
move to the different options, and to get into the submenus we have to
press “OK” button.
1. I/O configuration
Inside the “I/O configuration” menu there are specified the different options
for setting up the input, output and modulation parameters.
In order to move around the different options we have to use the “Up” and
“Down” buttons of the keyboard. Click on OK to edit the selected parameter
and Right/Left for changing it. Once it is configured press Cancel.
Terrestrial input (Input Ter)
In this option you will be able to configure the input parameters of the
terrestrial signal:
- Freq. (MHz): Input frequency of the multiplex that you wish to tune. In order
to introduce the frequency, press the “OK” button and the cursor will be
placed over the frequency. With the keys of the cursor, we can move through
all the digits and change the values. Press “OK” in order to save the value.
Options: 170-230 / 470-862 MHz.
- BW (Bandwidth): Selection of the input signal Bandwidth: 8MHz, 7MHz and 6MHz.
Main menu
1.I/O configuration
_ ___
2.System
3.SD Backup
4.CAM
TFF 310 CI
I/O configuration
1.Input Ter
_ ___
2.Out Ter
3.Out TV
4.Services config.
TFF 310 CI
Input ter
1.Freq 570000
2.Bandwith 8 MHz
TFF 310 CI
TSF 310
LCN:00004 arte HD
Summary of Contents for TFF 310 CI