User’s manual · TFF 310 CI
- 10 - TFF 310 CI version_en_2.0 FTE maximal
- Both: Once the loss of decryption of the CAM is detected, the rights will be sent several times until the
decryption gets back. In cases where it does not get back the module will make a reset of the CAM.
- CAM Reset after: It makes a reset of the CAM alter a set period of time.
Options: 0, 5 min, 10 min, 15 min.
- CI daily reset time: Time when the CAM is resetting when this option is enabled.
PRO 201
Note: From PRO 201 programmer you can only carry out the programming of a single module, in order to carry
out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX
MINI series field strength meter.
When you connect the PRO 201 programmer, it will proceed to recognize the
module and to show the main menu.
In the main menu are shown the different options for configuring the regenerator.
We have to use the “Up” and “Down” buttons of the keyboard in order to move to
the different options, and to get into the submenus we have to press “OK” button.
1. Manual
Inside the “manual” menu there are specified the different options for
setting up the input, output and modulation parameters.
1. This field shows the type of parameter that is selected at the moment.
Options: Input Terr, Out Terr, Out TV.
2. This field shows the parameter that is selected. In order to move
around the different options we have to use the “Up” and “Down” buttons
of the keyboard. Click on OK to edit the selected parameter and
Right/Left for changing it. Once it is configured press Cancel.
Terrestrial input (Input Ter)
In this option you will be able to configure the input parameters of the terrestrial
signal:
- Freq. (MHz): Input frequency of the multiplex that you wish to tune. In order to
introduce the frequency, press the “OK” button and the cursor will be placed over
the frequency. With the keys of the cursor, we can move through all the digits and
change the values. Press “OK” in order to save the value.
Options: 170-230 / 470-862 MHz.
- BW (Bandwidth): Selection of the input signal Bandwidth: 8MHz, 7MHz and 6MHz.
Terrestrial modulation (Out Terr)
These options allow configuring the DVB-T/DVB-H modulator of the device.
- Modulation: Output modulation format: 4 (4 QAM), 16 (16 QAM), 64 (64 QAM).
- Invert (Spectrum inversion): Activate or deactivate the spectrum reverse in the
modulation.
- GI (Guard interval): Allows selecting the guard interval of the modulation: 1/4,
1/8, 1/16 and 1/32.
- BW (Bandwidth): Selection of the Bandwidth of the modulated signal: 8MHz, 7MHz, 6 MHz and 5MHz. The 5MHz option
is only supported by DVB-H standard.
- Tx Mode (FFT Mode): 8K, 4K and 2k. The 4k option is only supported by DVB-H standard.
- FEC: Indicates the relationship between the redundant bits and the transmitted information bits: 1/2, 2/3, 3/4, 5/6 y
7/8. For example, in a FEC = 2/3 relation we will find 2 information bits and 1 redundant bit.
- Mode: Selection of the modulation standard: DVB-T and DVB-H.
Note: The output useful bits rate will depend on the following parameters: Bandwidth, guard interval, FEC
codification and modulation. In the
Attachment I you will find all the information related to the resulting useful bit
rate in each configuration.
TFF310CI *Input Ter
RF level: 013
>Freq: 474000
BW:
8
MHz
1
2
TFF 310 CI
>Manual< Config
Auto
TFF310CI *Input ter
RF level: 013
>Freq:
474000
BW:
8
MHz
TFF310CI *Out ter
Modulation: 64
>Invert: No
GI: 1/32
Summary of Contents for TFF 310 CI
Page 1: ...TFF 310 CI USER S MANUAL...