21
Press the
[
OK
]
key to call the selected function.
Press the
[
+
]
key to cancel the active function and to switch to measuring
mode.
–
If no key is pressed for 60
seconds,
the
instrument
returns
automatically
to
measuring mode.
Replacing the batteries / rechargeable batteries
Switching off the instrument:
Press and hold the
[
OK
]
key and the
[
+
]
key simultaneously.
Loosen the screw on the power pack and remove the power pack.
For the battery holder (order no. 83
22
237):
Replace alkaline batteries or NiMH rechargeable batteries. Ensure correct
polarity.
WARNING
Danger of explosion!
Do not throw used batteries into fire or try to open them by force.
Do not replace the batteries / rechargeable batteries in areas where there is a
danger of explosion.
Batteries / rechargeable batteries are part of the Ex approval.
Only the following types may be used:
–
Alkaline batteries – T3 – (not rechargeable)
Panasonic LR6 Powerline
Varta Type 4106
1)
(power one) or
Varta Type 4006
1)
(industrial)
–
Alkaline batteries – T4 – (not rechargeable)
Duracell Procell MN1500
1)
–
NiMHy rechargeable batteries – T3 – (rechargeable)
GP 180AAHC
1)
(1800
mAh) max. 40
°C ambient temperature.
Charge the NiMH power pack T4 (type HBT 0000) or T4 HC (type HBT 0100)
with the associated Dräger charger. Charge NiMH single cells for battery holder
ABT 0100 according to the manufacturer's specification. Ambient temperature
during charging: 0 to +40
°C.
1)
Not subject to BVS10 ATEX E 080X and PFG 10 G 001X performance approval.
WARNING
Danger of explosion!
The Dräger X-am 5600 must only be operated with battery holder ABT 0100
(X-am 5600), identified with a silver sticker.
For the NiMH power pack T4 (order no. 83
18
704)
/
T4
(order
no.
83
22
244):
Completely replace the power pack.
Insert the power pack into the instrument and tighten the screw, the
instrument switches on automatically.
Charging the instrument with NiMH power pack T4
(type HBT 0000)/ T4 HC (type HBT 0100)
Even if the instrument is not used, we recommend that you store the instrument
in the charger!
Insert the switched off instrument into the charger.
–
Display LED on the charger:
To maintain the lifetime of the batteries, charging is temperature controlled and
only performed in a temperature range of 5 to 35 °C. When this temperature
range is left, the charging is automatically interrupted and automatically
continued after the temperature range has been reached again. The charging
time is typically 4 hours.
A
new
NiMH
power
pack
reaches
its
full
capacity
after
three complete load/unload cycles. Never store the instrument for extended
periods (maximum 2
months) without being connected to a power source, as
this drains the internal buffer battery.
WARNING
Danger of explosion!
Do not charge underground or in explosion-hazard areas!
The chargers are not designed in accordance with the regulations for firedamp
and explosion protection.
WARNING
Danger of explosion!
Charge the NiMH power pack T4 (type HBT 0000) or T4 HC (type HBT 0100)
with the associated Dräger charger. Ambient temperature during charging: 0 to
+40
°C.
Charge
Fault
Full
Summary of Contents for Drager X-am 5600
Page 163: ...162 O2 1 Bump Test 21 O2 A1 A1 A1 1 2 OK A2 Dr ger X am 5600 A1 O2 A2 O2 A1 A2...
Page 228: ...227 O2 Bump Test 21 Vol O2 A1 A1 A1 A1 A2 OK A2 OK A1 O2 A2 O2 A1 A2...
Page 292: ...291 9LVLRQ DP 7 67 7 67 67 7 7 7 7 7 U JHU DP 2 m EW m 7 67 6 2 2 2...
Page 293: ...292 9RO 2 U JHU DP 5 2 2...
Page 294: ...293 67 7 67 7 67 2 U JHU 67 7 2 2 7 67 9LVLRQ 2 U JHU 8 5 2 U JHU 5 2 U JHU 6 2 U JHU 9LVLRQ 1...
Page 297: ...296 2 5 5 YRO 5 2 5 2 YRO 2 YRO 2 SSP 6 SSP YRO U JHU 2 2 9RO 6 SSP 2 SSP 2 2 PLQ 2 2 2 2...
Page 298: ...297 1 1 2 6 2 5 2 U JHU U JHU U JHU U JHU U JHU...
Page 302: ...301...
Page 303: ...302...