27
EN
-U
S
22
Swiveling device left
Signal is only available in conjunction with the Robacta Reamer V Twin:
-
Swiveling device is positioned on the left
23
Swiveling device right
Signal is only available in conjunction with the Robacta Reamer V Twin:
-
Swiveling device is positioned to the right
24
Reserve for relay OUT
Reserve signal for actuator (relay contact)
25
Parting agent in the dipping bowl
Signal is only available in conjunction with Robacta TC devices:
-
There is parting agent in the dipping bowl of the cleaning device
26
Clamp gas nozzle and cleaning motor on/start cleaning
Signal is only available in conjunction with the Robacta Reamer V Twin and Ro
-
bacta TC devices.
"Clamp gas nozzle and cleaning motor on" signal only on the Robacta Reamer V
Twin:
-
Activates the gas nozzle clamping device and the cleaning motor
"Start cleaning" signal on Robacta Reamer TC devices:
-
Activates the cleaning process
27
Gas nozzle free/"TC ready"
Signal is only available in conjunction with the Robacta Reamer V Twin and Ro
-
bacta TC devices.
"Gas nozzle free" signal only on Robacta Reamer V Twin:
-
Gas nozzle clamping device of the welding torch cleaning device is not holding a
gas nozzle
"TC ready" signal only for Robacta TC devices:
-
Welding torch cleaning device is ready
28
Reserve
29
Reserve
30
Inject parting agent
Signal is only available in conjunction with the Robacta Reamer V Twin and Ro
-
bacta TC devices:
-
Activates the spraying of parting agent
31
Parting agent filling level OK
Signal is only available in conjunction with the Robacta Reamer V Twin and Ro
-
bacta TC devices:
-
There is parting agent in the parting agent container
32
Cleaning motor up
Signal is only available in conjunction with the Robacta Reamer V Twin:
-
Activates the upward motion of the cleaning motor