![Fronius T.I.M.E. SYNERGIC Operating Instructions/Spare Parts List Download Page 52](http://html1.mh-extra.com/html/fronius/t-i-m-e-synergic/t-i-m-e-synergic_operating-instructions-spare-parts-list_2339412052.webp)
52
Fig.27
Fuses on board VM34B
Plug connector X5
primary voltage supply
Primary 380V~
F12 6.3 A slow-blow
Cooling-unit pump 380V~
F3 0.63 A slow-blow
Plug connector X6 for
415V mains reconnection
Plug connector X7 for
400V mains reconnection
Plug connector X8 for
380V mains reconnection
Fan for cooling unit 230V~
F4 0.315 A slow-blow
Fan 230V~
F5 0.315 A slow-blow
Plug connector X2 PWM
Vacant
Primary 0V~
F1 6.3 A slow-blow
Plug connector X1
for machine fan
Supply to NMI 4
20V~(-15V), F7 1 A slow-blow
Open-circuit voltage 36V~
F8 0.315 A slow-blow
Supply to NMI 4
20V~ (+15V / +10V / +5V)
F6 2 A slow-blow
Plug connector X3
Supply to NMI 4 control electronics
Wirefeeder motor (VR152) 42V~
F9 10 A slow-blow
Plug connector X4
voltage supply to BM 45.
Pull-Mig motor 42V~
F10 2 A slow-blow