34
EN 440 G2
EN 70 S-6
EN 288/7
Fe2 (SG 2/3)
CrNi 19 9
CrNi 18 8
AlMg 5
AlSi 5
Al 99,5
Rutile
Basic
CrNi
Flux-
cored
wire
Ar 97.5 CO
2
2.5
Ar 97.5 CO
2
2.5
Ar 100
1.0
2
3
7
S11
18
19
48
0.8
1.2
1.6
T.I.M.E.
T.I.M.E. II
T.I.M.E.
Fe1 (SG 2/3)
CO
2
100
S13
S14
S15 S16
Ar 82 CO
2
18
17
20
21
22
23
24
25
26
27
28
Ar 100
29
30
31
32
Ar 100
33
34
35
36
37
38
39
40
Metal
S43 S44
47
51
52
55
56
EPROM n°: C0027
Ar 82 CO
2
18
Ar 82 CO
2
18
Ar 82 CO
2
18
Ar 82 CO
2
18
Fig.4
Program overview table
MATERIAL
GAS %
PROG. CODE
T.I.M.E. 4-step slope dial
... 0.2 - 7.0 s.
Recommended setting: 1 s.
T.I.M.E. 4-step final-current dial
... Do not adjust this dial; dial must
be in the middle position
Wire-inch button
... for feeding the wire electrode into the torch
hosepack with no flow of gas or current
- Current socket with bayonet latch
... for
- connecting the interconnecting cable in MIG/MAG welding
- connecting the earth cable in TIG welding
- connecting electrodes or the earth cable in manual electrode welding
(depending on the type of electrode being used)
- Current socket with bayonet latch
... for
- connecting the earth cable in MIG/MAG welding
- current connection for TIG welding torch
- connecting electrodes or the earth cable in manual electrode welding
(depending on the type of electrode being used)
Torch control connection socket
... interconnecting cable
- Socket with bayonet latch
... interconnecting cable
Connection socket for FK71 cooling unit
... for connecting the control
plug for the cooling unit
N.B.!
If the cooling unit is not plugged in, the overtemperature indicator lights
up on the power source. Welding is not possible.
Optional gas pre-heating socket 230V / 80W
... for electrical supply
to gas pre-heater when CO
2
shielding gas is being used
Fig.5
Close up of "Internal 4-step parameters"
P-End dial
... 0 - 30 m/min (T.I.M.E.) or 1 - 10 (Power)
Recommended setting for T.I.M.E.: 5 and 9 m/min respectively
- Depending on the contents of the T.I.M.E. display, the scale refers to
wirefeed speed (0 - 30 m/min) or welding power (1-10)
- In the T.I.M.E. 4-step mode, P-End can be used to set the final wirefeed
speed; this set value is an absolute value, i.e. it is independent of
whatever value has been set for the welding power
Optional push/pull adjustment
... for adjusting the speed when using
a push-pull torch.
Program overview table
... gives information on the programmed
pulsed-arc, standard and T.I.M.E. programs.
- [S] ... only standard program is stored
- [P] ... only pulsed-arc program is stored
N.B.!
The program named EN 288/7 was welded in the context of a weld-
procedure approval test and only allows welding parameters that have been
covered in this test.
-
Background parameters
...remove the program overview table in
order to uncover further key parameters which can be set for the welding
process.
Gas pre-flow time dial
... 0.1 - 3.0 s.
Recommended setting: 0.1 s. (minimum)
Soft-start speed dial
... Minimum up to 100% of the pre-set wirefeed
speed
Recommended setting: 50% (medium)
Gas post-flow time dial
... 0.5 - 4.0 s.
Recommended setting: 2 s. (medium)
T.I.M.E. 4-step starting-current dial
... Do not adjust this dial; dial must
be in the middle position