19
EN
(1) Welding current axis
(2) Time axis
Current time = 400 ms
Welding cycle time = 2000 ms
DC_Inverter = 400 ms/2000 ms x 100 % =
20 %
IMPORTANT!
The inverter user documentation will be supplied with your system or
can be requested from Fronius Technical Support.
Calculating the maximum permitted welding current in the inverter load diagram
-
Find the inverter load diagram
-
Draw a vertical line on the diagram for the calculated inverter duty cycle
(DC_Inverter)
-
Multiply the primary current read off by the transformation ratio of the transformer
(e.g. 38) -> I_max_Inverter
Calculating the maximum permitted welding current
The maximum permitted welding current is the lowest of the three calculated currents
for the diodes (I_max_Diodes), transformer (I_max_Transf) and inverter
(I_max_Inverter)
Warning notices
on the device
The device is fitted with safety symbols and a rating plate. The safety symbols and rating
plate must not be removed or painted over. The safety symbols warn against operating the
equipment incorrectly, as this may result in serious injury and damage.
400 ms
2000 ms
(1)
(2)
5
6
Summary of Contents for DeltaSpot G2
Page 2: ...2 ...
Page 4: ...4 ...
Page 14: ...14 ...
Page 15: ...General information ...
Page 16: ......
Page 20: ...20 ...
Page 25: ...Control elements and connections ...
Page 26: ......
Page 35: ...Start up ...
Page 36: ......
Page 42: ...42 Threading the process tape Threading the process tape at the top 2 3 4 5 6 3 4 5 6 7 ...
Page 43: ...43 EN Threading the process tape at the bottom 7 8 9 10 8 9 10 11 ...
Page 45: ...Spot welding ...
Page 46: ......
Page 50: ...50 ...
Page 51: ...Troubleshooting and maintenance ...
Page 52: ......
Page 58: ...58 3 4 Lower gun arm 1 2 3 3 4 1 2 3 ...
Page 63: ...Appendix ...
Page 66: ...66 DRPDS1 0 RemoteControl PRO VSHFLI OHQJWK 4 300 006 ...