104
431
Power stage set is in boot
mode
1. Power stage set will be pro-
grammed by the Recerbo auto-
matically
1. Automatically corrected
2. Power stage set can not be
programmed automatically
2. Software update
3. Filter board defective
3. Change Recerbo
4. Recerbo defective
4. Change filter board
5. Power stage set defective
5. Change AC board
432
Consistent error in power
stage set management
1. Power stage set could not
communicate with the Recerbo
1. Restart inverter or do a soft-
ware update
2. Power stage set defective
2. Change AC board
3. Recerbo defective
3. Change Recerbo
433
Allocation error of dynamic
addresses
1. Power stage set could not
communicate with the Recerbo
1. Restart inverter or do a soft-
ware update
2. Power stage set defective
2. Change AC board
3. Recerbo defective
3. Change Recerbo
436
Problem while error trans-
mitting of the power stage
set
1. Power stage set could not
communicate with the Recerbo
1. Restart inverter or do a soft-
ware update
2. Power stage set defective
2. Change AC board
3. Recerbo defective
3. Change Recerbo
437
Problem with the internal
error handling
1. Power stage set could not
communicate with the Recerbo
1. Restart inverter or do a soft-
ware update
2. Power stage set defective
2. Change AC board
3. Recerbo defective
3. Change Recerbo
438
Problem while error trans-
mitting from power stage
set to Recerbo
1. Power stage set could not
communicate with the Recerbo
1. Restart inverter or do a soft-
ware update
2. Power stage set defective
2. Change AC board
3. Recerbo defective
3. Change Recerbo
445
Country setup information
faulty
1. Country setup information
faulty
1. Do a software update and
reload country setup fromsetup
menu
2. Old software (e.g after print
exchange)
2. Do a software update and
reload country setup fromsetup
menu
3. Impossible manual settings
in service menu
3. Check settings
4. Recerbo defective
4. Change Recerbo
447
Isolation failure detected
1. PV generator grounded
1. Use only ungrounded mod-
ules
2. PV generator grounding er-
ror
2. Check PV generator
3. Measuring circuit on power
stack defect
3. Change DC board. After-
wards if necessary AC board
448
Neutral wire fault
1. No neutral wire detected
1. Check wiring
2. Wrong setup
2. Check country setup
3. Bad contact: wall bracket <-
> inverter
3. Check AC wall bracket
screws
4. Filter board defective
4. Change filter board
Code
Description
Behaviour
Remedy
Summary of Contents for 10.0-3 480
Page 2: ...2 ...
Page 5: ...Allgemeine Informationen ...
Page 6: ......
Page 13: ...Fehler Suchhilfe ...
Page 14: ......
Page 33: ...Komponenten austauschen ...
Page 34: ......
Page 40: ...40 Gewindebuchsen in der Grundscha le tauschen 1 2 3 4 5 1 2 3 4 5 ...
Page 41: ...41 DE 6 6 ...
Page 73: ...Sicherheitstechnische Überprüfung ...
Page 74: ......
Page 86: ...86 ...
Page 89: ...General information ...
Page 90: ......
Page 97: ...Error location aid ...
Page 98: ......
Page 116: ...116 ...
Page 117: ...Changing components ...
Page 118: ......
Page 124: ...124 Replacing thread ed bushings in the base shell 1 2 3 4 5 1 2 3 4 5 ...
Page 125: ...125 EN 6 6 ...
Page 156: ...156 ...
Page 157: ...Safety Inspections ...
Page 158: ......
Page 170: ...170 ...
Page 171: ...Appendix ...
Page 176: ...176 Circuit diagrams Fronius Symo ...
Page 177: ...177 Circuit diagrams Fronius 15 0 ...
Page 178: ...178 ...
Page 179: ...179 ...