103
EN
Service class 4
Some of the class 4 status codes necessitate intervention by a Fronius-trained service en-
gineer.
Code
Description
Behaviour
Remedy
401
Communication error be-
tween Recerbo and power
stage set
1. Ribbon cable between pow-
er stage set and filter board
faulty or not connected proper-
ly
1. Check ribbon cable between
Recerbo and power stage set
2. Ribbon cable defective
2. Change ribbon cable
3. Recerbo not plugged in cor-
rectly
3. Check Recerbo plug
4. Recerbo defective
4. Change Recerbo
5. Power stage set defective
5. Change AC board
6. Filter board defective
6. Change filter board
406
Temperature sensor in DC
semiconductor module de-
fective
1. Defective temperature sen-
sor in semiconductor module
1. Change DC board
2. Defective circuit on the pow-
er stage set
2. Change DC board
407
Temperature sensor on the
power stage set
1. Defective temperature sen-
sor on the power stage set
1. Change AC board
2. Defective circuit on the pow-
er stage set
2. Change AC board
408
On the inverter an unac-
ceptably high DC injection
was detected
1. Asynchronous AC grid
1. Check AC grid
2. Power stage set defective
2. Change AC board
412
Adjusted fix voltage beyond
the accessible MPP range
1. Fix voltage was adjustable
too high or too low
1. Check adjustments in the
service menu
415
Wire shutdown tripped
1. Option card tripped a wired
shutdown
1. Automatically corrected, op-
tion card stopped the inverter
416 - 425
Communication error be-
tween power stage set and
Recerbo
1. Occurs once - PSP commu-
nication error
1. Automatically corrected
2. Unknown option card blocks
the inverter
2. Software update
3. Ribbon cable between filter
and power stage set defective
3. Change ribbon cable
4. Recerbo defective
4. Change Recerbo
5. Filter board defective
5. Change filter board
6. Power stage set defective
6. Change AC board
426
Charging intermediate cir-
cuit takes too long
1. Too less DC Power
1. Restart inverter or do a soft-
ware update
2. DC inductors not properly
connected
2. Check DC inductors screws
3. DC booster defect
3. Change DC board. After-
wards if necessary AC board
427
1. Software error
1. Update software
2. Measuring error on the pow-
er set
2. Change AC board
Summary of Contents for 10.0-3 480
Page 2: ...2 ...
Page 5: ...Allgemeine Informationen ...
Page 6: ......
Page 13: ...Fehler Suchhilfe ...
Page 14: ......
Page 33: ...Komponenten austauschen ...
Page 34: ......
Page 40: ...40 Gewindebuchsen in der Grundscha le tauschen 1 2 3 4 5 1 2 3 4 5 ...
Page 41: ...41 DE 6 6 ...
Page 73: ...Sicherheitstechnische Überprüfung ...
Page 74: ......
Page 86: ...86 ...
Page 89: ...General information ...
Page 90: ......
Page 97: ...Error location aid ...
Page 98: ......
Page 116: ...116 ...
Page 117: ...Changing components ...
Page 118: ......
Page 124: ...124 Replacing thread ed bushings in the base shell 1 2 3 4 5 1 2 3 4 5 ...
Page 125: ...125 EN 6 6 ...
Page 156: ...156 ...
Page 157: ...Safety Inspections ...
Page 158: ......
Page 170: ...170 ...
Page 171: ...Appendix ...
Page 176: ...176 Circuit diagrams Fronius Symo ...
Page 177: ...177 Circuit diagrams Fronius 15 0 ...
Page 178: ...178 ...
Page 179: ...179 ...