3.5 Technical specifications
3.5.1 PE1 Pellet 7-10 / PE1 Pellet 7-10 Unit
Description
PE1 Pellet 7
PE1 Pellet 10
Nominal output
kW
7
10
Output range
2 - 7
2 - 10
Heat output boiler element
37.6
37.6
Electrical connection
230V / 50Hz / fused C16A
Power consumption
1)
W
43
50
Boiler weight
kg
approx. 200
approx. 200
Weight per unit
approx. 415
approx. 415
Total boiler capacity (water)
l
approx. 25
approx. 25
Total boiler capacity Unit (water)
approx. 37
approx. 37
Boiler domestic hot water content
122
122
Pellet container capacity
35
35
Ash box capacity
14.5
14.5
Water pressure drop (ΔT = 20 K)
mbar
0.8
2.1
Permitted operating pressure (hot water)
bar
3
3
Permitted operating pressure (domestic hot
water)
6
6
Test over-pressure (domestic hot water)
9
9
Minimum boiler return temperature
Not applicable due to
internal return temperature control
Maximum boiler temperature setting
°C
90
Minimum boiler temperature setting
40
Permitted operating temperature
95
Permitted operating temperature (domestic
hot water)
110
Airborne sound level
dB(A)
< 70
Boiler class as per EN 303-5:2012
5
Performance indicator as per DIN 4708
NL = 1.2
Standby heat loss as per EN 15332
Q
B
= 1.24 kWh / 24 h
Permitted fuel
Fuel acc. to EN ISO 17225 - part 2:
wood pellets Class A1 / D06
1.The technical specifications of the optional components can be found in the enclosed supplier documentation
Technical data
3
Technology
Technical specifications
24
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com