❒ Screw in two carrying bolts (hexagonal bolts M6x100) to the left and right at the
bottom rear side of the controller far enough to ensure that the controller and insu‐
lation are supported adequately
4.5.10 Installing the cleaning port door and blank cover
NOTICE! Recommendation for easier maintenance: mount the cleaning port door on
the same side as the WOS lever!
❒ Use three Allen screws to mount the cleaning port door on the desired side
➥ Start with the screws at upper right!
❒ Attach the door handle for the cleaning port door using a round headed screw
❒ Install the blank cover for the side cleaning port on the opposite side
4.5.11 Installing the insulated door
The illustrations show the assembly for the door stop on the right. If the insulated door
is attached on the left, complete the following procedures with the sides reversed ac‐
cordingly.
4
Assembly
Installing the boiler
44
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at
All manuals and user guides at all-guides.com