Setting - Lambda values
System menu
System
Setting
Lambda values
Heating up time for lambda probe
Time for the heating up cycle of the lambda probe.
Residual oxygen content setpoint
Residual oxygen content which is regulated during
“
Heating
” status.
Maximum deviation of residual O2 from setpoint
Within this tolerance range, with reference to the residual
oxygen content setpoint, the residual oxygen controller
does not activate.
O2 setpoint increase for partial load
In partial load operation of the boiler, the residual oxygen
content to be reached is increased by the specified value.
No feed when residual O2 below
If the current residual oxygen content falls below the set
value, the fuel slide-in stops.
Maximum feed correction by O2 controller
Maximum correction factor, by which the residual oxygen
controller can change the infeed.
Residual oxygen content, above which fire is out
If the current residual oxygen content in “
Heating
” status
exceeds the specified value, the safety time begins to run.
O2 Controller max
Adjustable parameters for the residual oxygen controller.
NOTICE! Factory setting - do not change!
Slide-in control
Adjustable parameters for the fuel slide-in controller.
NOTICE! Factory setting - do not change!
Start value of the O2 regulator.
Adjustable parameters for the fuel slide-in controller.
NOTICE! Factory setting - do not change!
Residual oxygen above which the lambda probe is allowed
to switch off
If the boiler switches to “
Boiler off
” or “
Off
” mode, the
lambda probe heating remains active for at least 1 hour,
up to a maximum of 24 hours. If the residual oxygen
content exceeds the value set here, the lambda probe
heating is switched off.