2.2.8 Feed system module
AU-08
(Sensor 2)
AU-09
(Sensor 1)
AU-10
(Fallschacht-
deckel 2)
AU-1
1
(Fallschacht-
deckel 1)
AU-12
(V
erriegelung
Eingang)
AU-13
(Externe
Freigabe)
AU-14
(Netz)
AU-15
(Ausgang 2)
AU-16
(Ausgang 1)
(FR
AUM 10
)
CAN L
CAN H
+U
Bus
GND
+24V
GND
+24V
GND
+24V
IN
GND
+24V
IN
+24V
IN
+24V
IN
+24V
IN
+24V
IN
L1
N
L2
L3
L1
L2
L3
L1
L2
L3
F1 (17)
F2 (18)
F3 (19)
F4 (20)
F5 (21)
F6 (22)
AU-01
(Bus)
AU-02
(Bus)
AU-03
(Bus)
AU-04
(Versorgung 24V)
AU-05
(Versorgung 24V)
AU-06
(Verriegelung Ausgang 2)
AU-07
(Verriegelung Ausgang 1)
End jumper
Module address
Feed system module
Connection / Name
Note
AU-01
Bus
Port with cable – LICY paired 2x2x0.5;
⇨ See "Connecting the bus cable" [page 34]
❒ Caution! CAN L and CAN H must not be connected to +U
BUS
!
AU-02
Bus
Patch cable CAT 5 RJ45 SFTP 1:1 configuration
AU-03
AU-04
24V power supply
Connection cable
1)
2 x 0.75 mm
2
AU-05
AU-06
Output 2 latch
AU-07
Lock output 1
AU-08
Sensor 2
Connection cable
1)
3 x 0.75 mm
2
, N/O switch contact 254V (e.g.
connecting a light barrier)
AU-09
Sensor 1
AU-10
Gravity shaft cover 2
Connection cable
1)
2 x 0-76mm
2
AU-11
Gravity shaft cover 1
AU-12
Input latch
AU-13
External release
AU-14
Mains
Connection cable
1)
5 x 2.5 mm
2
AU-15
Output 2
Connection cable
1)
4 x 1.5 mm
2
, max. 0.75kW -7 400V
(e.g. connecting a feed screw)
AU-16
Output 1
Power connection and wiring
2
Expansion modules
Service manual Lambdatronic H 3200 for wood chip boiler | B1480721_en