4.13 Manual
4.13.1 Manual - Manual operation
System menu
Manual
Manual operation
When exiting the “Manual operation” menu, all active
parameters are automatically set to “OFF”! The parameters
displayed depend on the boiler configuration!
Stoker ON
▪ ON: The stoker screw drive is activated.
Feed screw ON
▪ ON: The feed screw drive is activated.
Suction screw of cyclone 1
▪ ON: The drive of the suction screw at cyclone 1 is
activated.
Suction screw of cyclone 2
▪ ON: The drive of the suction screw at cyclone 2 is
activated.
Rotary valve ON
▪ ON: The drive of the rotary valve is activated.
Screw 1
▪ ON: The drive of screw 1 on feed system module is
activated.
Screw 2
▪ ON: The drive of screw 2 on feed system module is
activated.
Bunker filling rotary agitator
▪ ON: In the case of rotary agitator with a separate drive
system, the head of the rotary agitator is operated
separately from the delivery screw.
WOS drive
▪ ON: The heat exchanger cleaning system is activated.
NOTICE! With PE1c Pellet, the WOS is activated via a
combined drive with the ash screw!
Back burn flap drive
▪ ON: Burn back flap is opened.
Oufeeder - manual
▪ ON: The stoker and feed screw drive is activated.
Ash screw
▪ ON: The ash screw drive is activated.
Tilt grate drive
▪ ON: The tipping grate is opened.
Rinse the condenser manually – only possible if boiler off /
on standby
▪ ON: The solenoid opens and the calorific value heat
exchanger is cleaned.
NOTICE! This parameter can only be activated when the
boiler is in “Standby” or “Boiler off” status.
Parameters overview
4
Manual
Service manual Lambdatronic H 3200 for wood chip boiler | B1480721_en
89