ENGLISH - 14
4.6 ACTIVATION
FRIGOMAT declines all and any liability for damage caused by failure to comply with the
following indications. This lack of compliance causes the warranty to terminate.
Connection of the machine to the water mains must be performed in compliance with
national regulations of the Country where the machine is installed.
To commission the machine, bring it to the place of use, checking what is requested for its
installation:
1. Electrical power supply 3 n earth (5 wires – only three-phase
mod.)
Electrical power supply L + N + earth (3 wires - only single-phase mod.);
2. Cold water mains supply (13° - 20°C, only water mod.);
3. Condensation water drain (only water mod.) and for the washing water.
•
Make sure the appliance is positioned on a solid, stable, flat and levelled surface.
•
Block the machine by acting on the relevant
brake lever on the rear wheels.
•
If the machine is air cooled, leave enough space
between the floor and the bottom of the
machine. Never block this space with closed
platforms, plinths or in any other way.
Never obstruct the ventilation grills on the
operator side (see fig. to the left).
•
Check the exact correspondence between the
voltage and power of the mains compared to
the values carried on the data plate applied on
the side of the panel.
•
Connect the machine to the electrical power supply system. Install a omnipolar master
switch upstream the appliance with minimum contact opening of 3 mm of adequate
power, with a fuse and circuit breaker protective system. Use an approved interlocking
plug to allow only the open circuit to connect and disconnect.
•
The cable must be well laid, without being rolled-up or overlapped. It must not be
exposed to blows or tampering. It must not be in the vicinity of liquids or water and heat
sources. It must not be damaged in any way. If so, before connecting the machine to
the mains, have it replaced by qualified personnel with another having a t5G4 H07RN-F
(400 V version), 3G4 H07RN-F (220 V / 1 version).
•
For safety purposes, make sure the earthing system to which the machine plug is
connected is compliant with standards and perfectly efficient.
Summary of Contents for GX2 A
Page 93: ...APPENDICI 2 ...
Page 97: ...APPENDICI 6 ...
Page 98: ...7 APPENDICI GX4 s03 Tav 1 12 OPTIONAL ...
Page 100: ...9 APPENDICI GX2 s03 Tav 2 12 OPTIONAL ...
Page 102: ...11 APPENDICI GX4 s03 A Tav 3 12 ...
Page 104: ...13 APPENDICI GX2 s03 A Tav 4 12 ...
Page 106: ...15 APPENDICI GX4 s03 W Tav 5 12 ...
Page 108: ...17 APPENDICI GX2 s03 W Tav 6 12 ...
Page 110: ...19 APPENDICI GX4 s03 Tav 7 12 ...
Page 112: ...21 APPENDICI GX2 s03 Tav 8 12 ...
Page 114: ...23 APPENDICI GX4 GX2 s03 Tav 9 12 ...
Page 116: ...25 APPENDICI GX4 GX2 s03 Tav 10 12 ...
Page 118: ...27 APPENDICI GX4 s03 Tav 11 12 400 50 3 220 60 1 230 50 1 ...
Page 120: ...29 APPENDICI GX2 s03 Tav 12 12 400 50 3 230 50 1 220 60 1 ...
Page 122: ...NOTE NOTES NOTES BEMERKUNG NOTA ...
Page 123: ......