34
Stand/Update
: 01.2019
Displayed text
Tip/remedy
Attention!
Double fusion!
Message is displayed when a fitting has been tried to fuse once
again. Nevertheless, if you intend double fusion on a fitting, you
must disconnect the fusion unit’s pins from the fitting after the
first fusion, and let it cool down (see the processing instructions
issued by the fitting manufacturer).
Defect/incorrect
barcode
Use a new barcode on an identical fitting, or correct the
entered code manually.
Let the device
cool down.
Protective function that prevents the device from overheating.
Let the device cool down. The fans reduce the temperature
of the device when it is switched ON.
Fusion stop
Fusion stopped at STOP key.
End of fusion
Fusion finished.
Checks
Checks on the fitting data and FRIAMAT preCHECK function.
Voltage … V;
frequency … Hz
Adjust generator, and acknowledge at STOP key.
Maintenance
date exceeded
Have the device serviced by FRIATEC GmbH or an authorised
service station.