33
Stand/Update
: 01.2019
09 Frequency out of
range
Frequency outside
of permitted range
during fusion.
Check frequency
of generator voltage
10 Fusion stop
Fusion stopped
at STOP key.
–
12 Device overheated Protective function
that prevents the device
from overheating.
Let the device cool down.
The fans reduce the
temperature of the device
when it is switched ON.
13 Operating voltage
failure
Supply voltage interrupted
(e.g. power failure during
fusion) or too low.
Check connection
conditions.
14 Power too low
Fitting’s power input is too
low. The FRIAMAT cannot
provide such a low power.
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
15 Power exceeded
The fitting’s power input
exceeds the capacity
of the FRIAMAT.
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
17
-
19
System error
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
23 Generator error
Generator possibly
not suitable for fusion.
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
30 Fan blocked
or defective
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
32 Temperature
sensor fault
One of the temperature
sensors defective in the
device
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
34 Temperature limit
reached
A temperature sensor
signals high heating levels
in the device
Let the device cool down.
The fans reduce the
temperature of the device
when it is switched ON.
50 USB interface fault USB transfer not possible
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533
70 Communication
fault
Data transfer has been
disrupted inside the device.
Contact the FRIATEC
service hotline:
+49 (0) 621 - 486 1533