19
Stand/Update
: 01.2019
CAUTION
Only original FRIATEC fusion plugs (art. no. 624529) may be used!
9. Connect the fusion plugs to the contact pins on the fitting.
10. The fusion plugs must be attached completely to the fitting’s pins,
i.e. over their whole internal contact length.
4.2
Reading in the barcode
1. Read in the barcode: use exclusively the barcode affixed to or provided
with the contacted fitting.
2. If the barcode label is missing or damaged, you can use the barcode
on an identical fitting from the same manufacturer and the same charge.
In cases of doubt, contact the fitting manufacturer’s hotline.
NOTE
It is forbidden to read in a replacement barcode on a different fitting!
3. Read in the barcode with a reader wand or scanner
(see also Sections 3.7 and 3.8).
4. A correctly read barcode is confirmed with an acoustic signal.
INFORMATION
When an acoustic signal is not emitted, examine the reader wand or scanner
for soiling or damage. If necessary, you can also perform the fusion in
emergency input mode (see Section 5.3)!
4.3
Starting the fusion procedure
CAUTION!
Danger of burning injury!
In rare cases, hot PE melt can exit when the fusion sequence malfunctions. A safety
distance of at least 1 m must be kept from the fusion site.