32
Stand/Update
: 01.2019
7.
Error messages / warnings / info
Irregularities during fusion cause error messages or warnings to appear on the
display of the FRIAMAT fusion unit.
INFORMATION
On the FRIAMAT prime eco, press the function key to view the displayed
error message in plain text!
INFORMATION
Should the FRIAMAT fusion unit output an error message or warning that is
not listed in the following and that cannot be explained or remedied despite
the plaintext description, contact our service h49 (0)621 486-1533!
No.
Displayed text
Meaning/causes
Remedy
01 Wrong barcode
Faulty / Wrong barcode
Use a new barcode of the
same batch or enter it
manually. Correct code.
02 Temperature
out of range
Ambient temperature
outside of permitted range.
You may have to tent over
or shield the fusion area
03 Resistance outside
of tolerance
Fitting’s electrical resistance
outside of tolerance.
Check that contacts
sit firmly and are clean.
If necessary, clean contacts
and replace the fitting.
04 Fitting’s wire
turn short circuited
Short circuit in the fitting’s
wire turn.
Replace fitting, and send it
in for analysis.
05 Fitting’s wire
turn interrupted
Current flow interrupted
Check the connection
between the fusion plug
and the fitting.
If OK, replace fitting, and
send it in for analysis.
06 Voltage outside
of tolerance
Deviation in fusion voltage
too high.
Notify authorised service
station.
08 Operating voltage
out of range
Operating voltage outside
of permitted range during
fusion.
Extension too long, or cross
section too small. Check
voltage and connection
conditions on the generator.