20
Stand/Update
: 01.2019
NOTE
Do not connect any other consumers during fusion!
You can stop the fusion procedure at any time by pressing the STOP key.
Fusion can be resumed after the fusion joint has cooled completely (and
all causes of the fault have been eliminated). Observe here the processing
instructions from the fitting manufacturer.
INFORMATION
When an acoustic signal is not emitted confirming the read-in process, examine
the wand or scanner for soiling or damage. If necessary, you can also perform
the fusion in emergency input mode (see Sections 5.5 and 6.3)!
Operating step
1.
“Pipe Processed?”
appears on the display. When applicable, confirm this
with the (START) or the (Next) function key.
2. The fitting data then appear again. These must be checked and confirmed
by the user.
3. Press the (START) key to initiate the fusion procedure. The ambient
temperature is measured, and the resistance of the connected fitting
determined ("Check" appears on the display). The connected fitting
and the FRIAMAT preCHECK function are now checked. On positive
results, fusion starts automatically. The display shows the fusion progress.
This shows in seconds the duration of fusion and the fusion time left.
4. “Fusion successful” on the display means: Fusion procedure has ended.
“Fusion time nom” and “Fusion time act” mean nominal and actual fusion
time and must agree.
5. Note the fusion parameters on the pipe/fitting. This also serves to prevent
double fusions.
6. “Fusion successful” with “Fusion time nom” and “Fusion time act”
must always be acknowledged with OK or, alternatively, with the START
or STOP key. The fusion procedure has ended, and the FRIAMAT fusion
unit is ready for the next fusion.