3.8 Scanner
The scanner reads in fusion barcodes and traceability barcodes without
physical contact. All you need to do is aim at the barcode and press the read
button. The barcode is scanned by means of a red light strip that must cross
over the whole barcode, whenever possible at the centre. The barcode is not
detected properly when the red light strip does not cross the whole barcode.
The optimal read results are obtained when the scanner is positioned at a small
distance over the barcode. When the barcode is read in successfully, the device
emits an acoustic signal.
NOTE
Protect the reading window from dirt and scratches!
The condition of the reading window has a direct effect on the capabilities of the
FRIAMAT scanner.
3.9
Protective cap for data interface
The USB port is found directly behind the protective cap. This data interface
functions as a service port. The protective cap for the data interface must be
screwed on at all times to prevent contaminants and moisture from reaching it.
3.10
Temperature probe
FRIAMAT fusion units can be used only on electrofusion fittings bearing a
barcode. When this is read in, the microprocessor controlled FRIAMAT fusion
unit regulates and monitors the supplied energy fully automatically and defines
the fusion time as a function of the ambient temperature. This ambient temper-
ature is continuously measured by the temperature probe on the fusion cable.
Make sure that both the temperature probe and the fusion fitting are exposed to
the same ambient temperatures. Avoid adverse processing situations, e.g.
where the probe is exposed to intense sunlight and the fitting is in the shade.
The temperature probe must be protected against damage.