Technical details
Technical details*
FRIAMAT prime cco
Input voltage range
AC 190 V – 250 V
Frequency range
44 Hz...66 Hz
Stromaufnahme
AC 16 A max.
Input current
3,5 kW
Generator rated output
for fittings
d 20 – d 160
d 180 – d 900
~ AC 2,4 kW
~ AC 5,0 kW
Unit fuse
16 A slow acting
Housing
international protection IP 54 DIN EN 60529
protection class I DIN EN 60335-1
Connecting cable
5 m with shaped plug
Fusion cable
4 m with fitting connector, ø 4 mm
Barcode type
code 2/5 interleaved according to
ANSI HM 10.8 M-1983 and ISO CD 13950/08.94
code 128 as defined under ISO 12176-4
Operating temperature
range**
-20°C...+50°C**
Fusion current monitoring
short circuit 110 A
short circuit 1.70 x IN
interrupt 0.25 x IN
Fusion voltage
max. DC 48V
Data transfer interface
USB / Bluetooth (prepared)
Protocol format
PDF, CSV, FTD
Protocol memory
20.000
Languages
Bulgarian, Croatian, Czech, Danish, Dutch,
English, Estonian, Finnish, French, German,
Hungarian, Italian, Latvian, Lithuanian, Polish,
Portuguese, Romanian, Russian, Slovakian,
Slovenian, Spanish, Swedish, Turkish
Dimensions W x D x H
260 x 500 x 340 mm
Weight
approx. 18 kg
Accessories
operating instructions, transport box
Overvoltage classification
Category II
Approval/quality
CE, ISO 9001, WEEE Reg. No. DE 49130851,
RoHS, REACH
*