Now we have counter bus running, we can select any channel connected to the bus A and
configure it as OPMWB. For instance we can select channel 21, set the leading edge (register A)
at 0 and trailing edge at 499, running on bus A, with a positive polarity (output is set at leading
edge etc.).
This gives us a PWM at 1kHz with 50% duty cycle.