9. Using a 22 mm
wrench, loosen the
valve stem from the
valve body.
10. Remove the valve
stem and plunger.
11. Inspect the
plunger for a dam-
aged or worn seal.
Inspect the valve
stem and seat for
scale build-up.
Replace as nec-
12. Reinstall the valve
plunger and stem.
Reinstall the stem to
the valve body.
13. Reinstall the valve
coil and retaining nut.
Reinstall the valve
stem cap.
14. Using a 14 mm
wrench, tighten the cap
to the stem.
15. Reinstall the valve.
16. Tighten both fit
-
tings.
17. Reattach the power leads to the coil.
18. Replace the control board bracket.
19. Replace the machine’s surround and right side panel.
20. Replace the machine’s top panel.