FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
55
TRIPOLI ARCH DOOR INSTALLATION
REGENCY
®
OPTIONS
A non-combustible material of 12" (305mm) above the Arch and 6"
(153mm) on each side must be used. The Arch Door also requires steel
stud framing above and on each side of the unit (refer to Diagram 1).
Diagram 1
Note:
The facing material has to go on after the unit is set.
1) Remove Glass Door.
2) Remove 2 screws and bracket as indicated (refer to Diagram 2).
3) Install On/Off switch (refer to Diagram 3).
Diagram 2
Diagram 3
Remove bracket
Remove both screws
On/Off Switch
Control
Mounting
Bracket
4) Place bracket under the Flange. Secure with 2 screws as indicated
in Diagram 4.
5) Loosen the 3 x #8 Phillips Head Screws located on the inside top
of the outer frame of the appliance (refer to Diagram 5).
3 x #8 Phillips
Diagram 4
Diagram 5