FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
22
VENTING
Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P36D-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.
FPI Direct Vent Flex System Termination Kit (Part # 946-515) includes all the parts needed to install the P36D-1 with a maximum run of
4 feet.
1)
6-7/8" dia. fl exible liner (4 ft. length)
2)
4" dia. fl exible liner (4 ft. length)
3)
spring spacers (4)
4)
thimble
(2)
5)
AstroCap
termination cap (1)
6)
screws
(12)
7)
tube of Mill Pac (1)
8)
plated
screws
(8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
If longer runs are needed, the FPI Direct
Vent system (Flex) # 946-516 includes all
the parts needed to install the P36D-1 with
a maximum 10' run.
1)
6-7/8" dia. fl exible liner (10 ft. length)
2)
4" dia. fl exible liner (10 ft. length)
3)
spring spacers (7)
4)
thimble
(2)
5)
AstroCap
termination cap (1)
6)
screws
(12)
7)
tube of Mill Pac (1)
8)
plated
screws
(8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from FPI may be used for Flex installations.
INSTALLATION
Summary of Contents for Regency P36D-LP1
Page 7: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 7 INSTALLATION UNIT DIMENSIONS...
Page 50: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 50 FLUSH BAY DOOR OPTIONS...
Page 57: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 57 CAST FACEPLATE...
Page 66: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 66 REPLACEMENT PARTS LIST...