FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
43
WIRING DIAGRAMS
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
(Do not cut the ground terminal off under
any circumstances.)
NOTE: Even if the fan is not purchased
with the unit, it is still a good idea
to bring power to the receptacle box
(provided with the unit) in case the
fan is installed at a later date.
CAUTION: Label all wires prior
to disconnection when servic-
ing controls. Wiring errors can
cause improper and dangerous
INSTALLATION
Ground
Green
Neutral
Live
Black
Red
Red
Fan Thermodisc
(normally open)
Ground
ON
OFF
Rotary Speed
Control
120V AC
60 Hz
Fan
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(for mobile home)
Star washer
Piezo
Ignitor
To Thermocouple IN
Pilot
Assembly
HI
LO
OFF
ON
P
IL
O
T
Gas
Pilot
Thermopile
Thermocouple
Electrode
Remote Transmitter
(Optional)
ON
OFF
Regency
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Brown
Red
T-Stat
Black
White
"S.I.T" Valve
Burner ON
OFF
Thermostat
(To THTP)
(To TH)
White
Gas
In
For
NATURAL GAS
Units and Units
NOT
Equipped with DC Spark Boxes
Summary of Contents for Regency P36D-LP1
Page 7: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 7 INSTALLATION UNIT DIMENSIONS...
Page 50: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 50 FLUSH BAY DOOR OPTIONS...
Page 57: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 57 CAST FACEPLATE...
Page 66: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 66 REPLACEMENT PARTS LIST...