FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
10
INSTALLATION
The
HeatWave
Duct Kit and the Heat
Release Kit have different clearance
and framing requirements, check the
HeatWave
and Heat Release manual
for details.
Heat Release Kit
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.
Clearance to Combustibles from:
Back
0"
(0mm)
Side
0"
(0mm)
Floor
0"
(0mm)
NOTE: The minimum fl oor clearance must be maintained from the top surface of the carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Ceiling
from top of unit.
32"
(1016mm)
Side Wall Clearances:
Bay or Flush Front
6"*
(152mm)
Barcelona
Front
6"*
(152mm)
Hampton Cast Faceplate
6"*
(152mm)
Kensington Front
6"*
(152mm)
Balmoral & Westminster Front
6"*
(152mm)
* Measured from Surround or Front. See Regency
®
Clearances section for dimensions.
Horizontal Vent Clearances:
Top
2"
(51mm)
Side
1-1/2"
(38mm)
Bottom
1-1/2"
(38mm)
Vertical Vent Clearances
1-1/4"
(32mm)
Alcove Clearances**:
Max.
Depth
36"
(914mm)
Min.
Width
48"
(1219mm)
Min.
Height
72"
(1829mm)
**Approved for one sidewall installation only when using Barcelona Front.
WARNING: Fire hazard is an extreme risk if these clearances are not adhered to.
CLEARANCES
Barcelona with Double Screen Door Installations
To install the combination of the Barcelona front and screen
doors you must use
non-combustible mantel
in conjunction with
the already
required framing specs for the Barcelona front
.
Steel studs and non-combustible material on the facing must be
adhered to.
IMPORTANT: See Barcelona & Palace™ Series Framing Note for framing note on
Barcelona Front and Palace™ Series Fronts.
Summary of Contents for Regency P36D-LP1
Page 7: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 7 INSTALLATION UNIT DIMENSIONS...
Page 50: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 50 FLUSH BAY DOOR OPTIONS...
Page 57: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 57 CAST FACEPLATE...
Page 66: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 66 REPLACEMENT PARTS LIST...