FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
39
INSTALLATION
5) Position Log 02-53 across the cut outs in
Logs 02-75 and 02-51 with the notch on the
left side of the log fi tting into the 2nd grate
tab.
Cutouts
2nd Grate Tab
02-53
02-75
02-51
02-51
02-53
Notch
Bracket
Bracket
02-51
02-75
4) Place Log 02-51 on the front right side of
the burner. Push the back of the log against
the 2 brackets with the notch on the bottom
right side of the log fi tting into the right side
of the grate.
LOG SET
INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.
The gas log kit (Part # 780-930) contains the
following pieces:
a) 02-75 Rear
Log
b) 02-55 Middle Left Log
c) 02-50 Front Left Log
d) 02-53 Center Left Log
e) 02-51 Front Bottom Log
f) 02-54 Center
Right
Log
g) 02-52 Middle
Right
Log
h)
Embers
NOTE: If you will be installing the optional
Brick Panels, install the Brick Panels
prior to installing the logs.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care -
do not force into position.
2) Sprinkle the vermiculite all over the top of
the base brick panel.
3) Place the Log 02-75 on the rear log support
pins with the fl at side to the back.
The "02" refer numbers (i.e. 02-75) are
molded into the rear of each log.
OPTIONAL
BRICK PANELS
1)
Undo the bottom 2 door latches and open
and remove glass door. Remove logs.
Note: The logs must not be in the unit.
2)
Insert the back brick panel fi rst by carefully
slipping it between the back wall of the fi rebox
and the rear log bracket.
3)
Put the side panels in next. Slide them in
from the front and push them fl at up against
the wall. Be very careful not to scratch them
on the fi rebox hardware.
4)
Install the 2 brick retaining clips, one on
each side.
02-75
Note:
If the bottom brick panel must be removed:
Remove the Rear Log Stand, then remove
the Burner Tray.
02-75
02-55
02-52
02-50
02-53
02-51
02-54
02-51
Notch
6) Position Log 02-54 across the cutouts in
Logs 02-51 and 02-53. The notch in the
bottom right end fi tting against the 5th grate
tab.
Summary of Contents for Regency P36D-LP1
Page 7: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 7 INSTALLATION UNIT DIMENSIONS...
Page 50: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 50 FLUSH BAY DOOR OPTIONS...
Page 57: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 57 CAST FACEPLATE...
Page 66: ...FPI P36D 1 Zero Clearance Direct Vent Gas Fireplace 66 REPLACEMENT PARTS LIST...