Shutting down and restarting the automatic feeder
45
5. Connect the teat to the feeding station valve (rationed mode) or the mixer jar (ad lib mode).
Use a new hose for this connection.
The hose must be installed at a gradient to the automatic feeder without sag-
ging. This makes it easier for calves to consume feed and facilitates draining the hose (see
figure).
50-80 cm
10-15 cm
Hose with gradient between teat and feding station valve
If your automatic feeder has a mixer drain valve, connect the mixer drain valve to the drain
channel. Use a new hose for this connection.
6. Insert the mains plug into the outlet that your service technician created for the automatic
feeder during initial startup.
7. Switch on the automatic feeder using the control switch.
Failure, HE not filled
appears in the display of the hand terminal.
8. Press
.
9. Choose
> Device data
to go to the
Time
or
Date
submenu.
•
In
Time
, you enter the time of day using the number keys.
•
In
Date
, you enter the date using the number keys.
•
In
Format
, you use
to select the desired date format.