Appendix
129
9.4
Automatic feeder shutdown checklist
Shutdown
OK?
1.
Run cleaning cycle.
2.
Drain water from boiler, solenoid valves, pressure valve, and volume control valve.
(In
case of frost risk)
2.1
Close water tap.
2.2
On hand terminal using
> Water Bo. > Start?
Dispense water into feeding box.
2.3
Disconnect water hose between water solenoid valve and boiler.
2.4
Open vent screw on boiler cover and drain boiler.
2.5
Re-attach water hose and tighten vent screw.
3.
Turn off automatic feeder and disconnect mains plug.
4.
Disconnect and dispose of water hose.
5.
Tip out liquid in mixer.
6.
Disconnect and dispose of hose between teat and feed station valve or mixer.
7.
Disconnect hose between mixer drain valve, if fitted, and drain channel.
8.
Seal cable glands for antennae with dummy plugs.
9.
Clean outside of automatic feeder with damp cloth.
10.
Empty milk powder container.
11.
Remove powder container protective grid.
12.
Basic cleaning of milk powder container and dosing unit
13.
Store automatic feeder in a dry and frost-free location