100
Running the automatic feeder
•
In
Date
, you enter the current date.
•
Repeat the recalibration in order to check your results.
•
Calibrate additional liquid components using the same method.
6.7.2.1.1 Recalibrating using the calibration scale:
The automatic feeder determines the actual value using the built-in automatic calibration scale
(additional equipment). You only have to recalibrate the detergent manually.
Proceed as follows to calibrate detergent using the calibration scale:
1. Choose
> Calibration
to go to the
Components
submenu.
2. In
Detergent
, you recalibrate the cleaning agent.
•
Confirm
Detergent
by choosing
.
•
In
Set quantity
, you can check the amount of cleaning agent that the automatic
feeder will dispense.
•
In
Runtime
, you can check the time in which the automatic feeder will dispense
cleaning agent.
•
In
Date
, you can check when the cleaning agent was last recalibrated.
•
Confirm
Start?
by choosing
.
•
Confirm
Exit automatic mode?
by choosing
This message is only displayed
if your automatic feeder is still operating in automatic mode.
•
Place the calibration box into the mixer jar and confirm the prompt
Calibration box
used?
by choosing
.
•
Detergent is dispensed into the calibration box.
•
Confirm
Confirm value....
by choosing
.
•
In
Date
, you enter the current date.
•
Remove the calibration box from the mixer jar.
•
Repeat the recalibration in order to check your results.
Summary of Contents for TAP5-CH2-25
Page 2: ......
Page 6: ...6 Table of contents ...
Page 102: ...102 Running the automatic feeder ...
Page 119: ...Appendix 119 9 Appendix 9 1 Feeding 9 1 1 Standard feeding plans 9 1 1 1 Group A ...
Page 120: ...120 Appendix 9 1 1 2 Group B 9 1 1 3 Group C ...
Page 121: ...Appendix 121 9 1 1 4 Group D ...
Page 122: ...122 Appendix 9 1 1 5 Template for individual feeding plan ...
Page 123: ...Appendix 123 9 1 2 Basic principle of interval feeding ...