Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
56
Dialogue window Details Data Recording
Pos. Description
1 Basic
data
These cannot be edited.
Recipe
Name of the currently used recipe.
Username
First- and surname of the logged-in user.
2
Length correction for production length (only if running meter recording is
activated)
Figure 2: Correction running meters
Correction running meters
Pos. Description
1 Measurement
point
2
stranding point
3 Post-forming head
4 Capstans
5
Reel end product
Table 1: Correction running metres
Here you can enter the length of the material from the measuring point
(1) or from the strand point (2) to the reel (5). The value is displayed in the
quality protocol. When rewinding, this length can then be separated from
the end product.
Note that the display stops in the histogram as soon as you stop the
stranding machine. However, the measurement (and control) continues.
The data recording is paused (not stopped) as soon as the value
“Minimum speed for data recording” (refer p. 23) is undershot. If the
machine is restarted and production continues and the speed threshold is
exceeded again, the data recording also continues.
3
Order number (internal or external)
4 Product
1
2
3
4
5