Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
44
Detail view channel
Pos. Description
2
Reference value of the strand tension, black line
Adjusting the value via drag and drop or direct input.
3
Upper threshold, orange line
Adjusting the value via drag and drop or direct input.
4 Upper
pre-alarm, green line
This value cannot be changed here. It is defined in the recipe manager as
a percentage deviation from the upper threshold.
5
Lower threshold, orange line
Adjusting the value via drag and drop or direct input.
6 Lower
pre-alarm, green line
This value cannot be changed here. It is defined in the recipe manager as
a percentage deviation from the upper threshold.
7 Wire-break detection consisting of two parameters
Threshold for force (herein 100N) and time interval (herein 0.3s). If the
threshold is exceeded by more than 0.3s, the wire break alarm is
triggered.
Adjusting the value (force only) via drag & drop or direct input.
8; 9
Lower and upper limits of the bar display
This is where you can define the visible area of the bar display. By
entering values directly, you can freely scale the display area, limiting the
view to the required section.
Adjusting the values with direct input.
If your input is not accepted and an error message “Enter a valid value”
appears, thresholds or reference value are in a range that would no longer
be displayed. Initially, change this value. E.g. The upper threshold is 800N
and the upper end of the bar display is at 1000N. The top end needs to be
changed to 750N. In this case, you must first adjust the upper threshold
to less than 750N, in order to perform the change.
This also applies if the value blocking the input, such as thresholds, is not
displayed in the bar display.