Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
27
6.4.10
Relay outputs
Figure 17: Basic setting – Relay outputs
Each RTM X42 receiver module has four relay outputs to which individual trigger
functions can be assigned. In the “Trigger function” selection list, you can select the
appropriate conditions that trigger the switching of the relay.
In the column “Invert output signal” the function of the relay can be reversed. By default,
the relay is disabled, when triggered, it is activated. The inversion activates it and the
triggering de-activates it.
Refer to the Installation and Operating Manual RTM X42.Modbus
6.4.11
Basic setting — channel assignment
A channel consists of a force sensor and a brake actuator. This is where you configure
this assignment.
A channel corresponds to a bar graph in the home screen. Each channel must be
assigned a force sensor. Optionally, a brake actuator can also be assigned to a channel.
Attention
When you assign a brake actuator to a channel, you must ensure
that the corresponding brake actuator also acts on the strand of the
force sensor associated with the channel.
Otherwise, the automatic tension control will not function.
Basic setting — channel assignment
Column Description
Force sensor
List of configured and connected force sensors
Brake actuator
Selection list with the names of all configured brake
actuators. Each brake actuator can only be used once.
Channel name
This name appears in both the bar graph and the histogram.
This is where it makes sense to use a maximum of four
characters.
Table 8: Basic Setting - Channel Assignment