TROUBLE-SHOOTING CHART
5G Paint Mixer Instruction Manual
27
The START light is on and
the top plate clamps on the
container, but mixer will
not run.
to make sure that the mixer is on a
dedicated line.
• Connect to dedicated line.
if front door closed.
if the problem is a loose motor
coupling set screw.
the reset button.
for loose or broken wire in the
shake motor cabling.
shake motor.
• Close the door.
• Tighten DC motor
coupling set screw.
• Press blue reset button
located on overload relay.
• Tighten or replace wire.
• Replace shake motor
cabling if necessary.
• Replace wire.
• Contact Customer Service
for assistance.
• Replace the shake motor.
The mixer starts slowly
and then increases to nor-
mal speed in a few sec-
onds.
shake motor V-belt tension.
• Adjust the shake motor V-
belt tension.
The DC motor runs, but the
top plate does not move.
for a loose set screw in one of the
DC motor couplings.
key and set screw on timing gears.
• Tighten set screw(s).
• Tighten key and set screw.
The mixer stops before
completing shake cycle.
for broken or loose wire in the DC
motor cabling.
• Replace DC motor cable.
The mixer speeds up and
slows down. The START
light is blinking.
if the front door is making contact
with the safety switch in the con-
trol box.
for a broken wire in DC motor
cabling.
• Adjust safety switch.
• Replace DC motor cable.
The mixer crushes or
throws cans.
Clamping force may be out of adjust-
ment.
• Adjust clamping force as
required.