34
Provincial Road n.78 Km 12.150
33050 Mortegliano (UD) – Italy
Tel. +39.(0)432.992482 – +39.(0)432.993557
Fax +39.(0)432.931280
Sito web:
www.flysynthesis.com
e-mail:
Maintenance Manual
FLY SYNTHESIS TEXAN
TOP CLASS 580 ISR
(For Rotax 912 ULS
versions)
Identification: MM_TC_580_Rev.2
Page: 34 of 77
Date: 15/02/11
Issued: C. Cosatto
Verified: C. Cosatto
Approved: C. Cosatto
Revision Description:
Placard update
9.1 INSPECTIONS
Inspections are composed of daily and scheduled inspections.
1.
Daily Inspections
, includes refuelling, fuel system draining and pre flight
inspection.
2.
Scheduled Inspections
per flight time are planed in a cycle of 50 flight hours,
to match the engine manufacturer requirements, these are composed of the
following inspection types: First 25 hour inspection; 50 hourly inspection; 100
hourly/Annual inspection and 200 hourly inspection.
The normal cycle repeats itself per following table:
Flight Time
25
50
100
150
200
250
300
350
400
Inspection Type
25
50
100
50
200
50 100
50
200
Flight Time
450
500
550
600
650
700
750
800
Inspection Type
50
100
50
200
50 100
50
200
Flight Time
850
900
950
1000
1050
1100
1150
1200
Inspection Type
50
100
50
200
50 100
50
Overhaul
The
25
hours inspection should be carried out only
once after the first 25 flying hours
of the airplane. It is also done once after an engine change, engine or airplane overhaul or
major repair due an accident or other major damage.
Other limited maintenance periods for certain equipment are listed separately.
9.2 DAILY INSPECTION
Daily inspections can be carried out by either the owner or by the maintenance person.
9.2.1 REFUELING
1.
Magnetos
Check OFF
2.
Master switch
ON
3.
Fuel quantity
Check
4.
Master switch
OFF
5.
Tank filler cap clean, and then open
6.
Fill the required amount of fuel per flight plan
7.
Tank filler cap
Close, check flush with top of wing
8.
Master switch
ON, check fuel quantity
9.
Master switch
OFF
10.
Record amount of fuel in airplane log
NOTE:
For
Rotax engines,
the recommended fuel is
95 Octane or higher
unleaded
motor fuel. If leaded fuel is used, or 100LL Fuel, engine maintenance checks including
spark plugs change, must be carried out more often. Consult ROTAX Maintenance
Manual.