-The power grid must be adapted to the power requirements of the appliance, and is grounded.
Do not disconnect and reconnect the appliance to the power supply when in operation.
Do not pull on the power cord to disconnect it from the power supply.
If the power cord is damaged, it must be replaced by the manufacturer, its technician or a qualified person to
guarantee safety.
Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance is wet.
Before connecting the appliance to the power supply, check that the connection unit or socket to which the
appliance will be connected is in good condition and shows no signs of damage or rust.
In stormy weather, disconnect the appliance from the power supply to prevent it from suffering lightning
damage.
Do not immerse the appliance in water or mud.
WARNINGS CONCERNING APPLIANCES CONTAINING REFRIGERANT R32
R32 refrigerant is classed under category A2L as mildly flammable.
Do not release R32 fluid into the atmosphere. These are fluorinated greenhouse gases, covered by the Kyoto
Protocol, with a Global Warming Potential (GWP) of 675 (European regulation EU 517/2014).
The appliance must be stored in a well-ventilated location away from all ignition sources.
Install the unit outdoors. Do not install the unit indoors or in an enclosed and non-ventilated outdoor location.
Do not use means for accelerating the defrosting or cleaning process other than those recommended by the
manufacturer.
The appliance must be stored in a room without any permanent ignition source (such as open flames,
operating gas appliance or operating electric heating).
Do not perforate or incinerate.
Please note that R32 refrigerant may give off a certain odour.
In order to comply with the applicable standards and regulations in terms of the environment and installation,
in particular French decree No. 2015-1790 and/or European regulation EU 517/2014, a leak test must be
performed on the cooling circuit at least once a year. This operation must be carried out by a specialist certified
to test cooling appliances.
Please keep the display controller in a dry area, or well close the insulation cover to protect the display
controller from being damaged by humidity.
INSTALLATION AND MAINTENANCE
The appliance may not be installed close to combustible materials, or the air duct inlet of an adjacent building.
With some appliances, it is essential to fit a "protection grid"-type accessory if the unit is installed in an area
with uncontrolled access.
During installation, troubleshooting and maintenance, pipes may not be used as steps: the pipe could break
under the weight, spilling refrigerant and possibly causing serious burns.
When servicing the appliance, the composition and state of the heat transfer fluid must be checked, as well as
the absence of any traces of refrigerant.
During the annual appliance sealing test in accordance with applicable legislation, the high and low pressure
switches must be checked to ensure that they are securely fastened to the refrigerant circuit and that they cut
off the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around the cooling components.
Before beginning work on the cooling circuit, stop the appliance and wait for a few minutes before fitting the
temperature and pressure sensors. Some elements such as the compressor and piping may reach temperatures
in excess of 100°C and high pressures with the consequent risk of severe burns.
Do not braze or weld the pipe if there is refrigerant inside machine. Please do not charge the gas when in a
confined space.
MAINTENANCE : WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT
Summary of Contents for 74139
Page 2: ......
Page 4: ......
Page 13: ...9 2 Dimension unit mm Model FSP 05...
Page 14: ...10 Model FSP 08 FSP 11...
Page 15: ...11 Model FSP 14...
Page 22: ...18 Dry contact timer connection Timer Dry contact pump connection...
Page 30: ...26 8 Exploded Diagram Model FSP 05...
Page 32: ...28 Model FSP 08 FSP 11...
Page 35: ...31 Model FSP 14...
Page 47: ...43 2 Dimensiones mm Modelos FSP 05...
Page 48: ...44 Modelos FSP 08 FSP 11...
Page 49: ...45 Modelos FSP 14...
Page 65: ...61 8 Diagrama Explosionado Model FSP 05...
Page 67: ...63 Model FSP 08 FSP 11...
Page 70: ...66 Model FSP 14...
Page 82: ...78 2 Dimension mm Mod le FSP 05...
Page 83: ...79 Mod les FSP 08 FSP 11...
Page 84: ...80 Mod le FSP 14...
Page 100: ...96 8 Sch ma Eclat Mod le FSP 05...
Page 102: ...98 Mod le FSP 08 FSP 11...
Page 105: ...101 Mod le FSP 14...
Page 117: ...113 2 Dimension mm Modell FSP 05...
Page 118: ...114 Modell FSP 08 FSP 11...
Page 119: ...115 Modell FSP 14...
Page 134: ...130 8 Explosionszeichnung Modell FSP 05...
Page 136: ...132 Modell FSP 08 FSP 11...
Page 139: ...135 Modell FSP 14...
Page 151: ...147 2 Dimensione mm Modelli FSP 05...
Page 152: ...148 Modelli FSP 08 FSP 11...
Page 153: ...149 Modelli FSP 14...
Page 169: ...165 8 Exploded Diagram Model FSP 05...
Page 171: ...167 Model FSP 08 FSP 11...
Page 174: ...170 Model FSP 14...
Page 186: ...182 2 Dimensie mm Model FSP 05...
Page 187: ...183 Model FSP 08 FSP 11...
Page 188: ...184 Model FSP 14...
Page 195: ...191 Dry contact timer verbinding Timer Dry contact pomp aansluiting...
Page 203: ...199 8 Ge xplodeerd Diagram Modellen FSP 05...
Page 205: ...201 Modellen FSP 08 FSP 11...
Page 208: ...204 Modellen FSP 14...
Page 220: ...216 2 Dimens o mm Modelo FSP 05...
Page 221: ...217 Modelo FSP 08 FSP 11...
Page 222: ...218 Modelo FSP 14...
Page 229: ...225 Conex o do temporizador de contacto seco Cron metro Conex o da bomba de contacto seco...
Page 237: ...233 8 Diagrama Explodido Modelo FSP 05...
Page 239: ...235 Modelo FSP 08 FSP 11...
Page 242: ...238 Modelo FSP 14...
Page 250: ......
Page 251: ......
Page 252: ......