TECHNICAL DATA
65
FC
01- CA
| Flow Meter
9 .4 .2 Transistor outputs
(DC)
Pin selection:
Signal name
Pin XAH
Polarity
/ ERROR emitter
1
-
/ ERROR collector
2
+
/ BUSY / PULSE emitter
3
-
/ BUSY / PULSE collector
4
+
Limit Switch 2 emitter
5
-
Limit Switch 2 collector
6
+
Limit Switch 1 emitter
7
-
Limit Switch 1 collector
8
+
Voltage level
Low level - active:
U
ce
< 0.8 V at I
C
< 10 mA
U
ce
< 1 V at I
C
< 100 mA
High level - passive:
U
ce
< 48 V
U
ce max
= 60 V
max. leakage current ≤ 25 µA
Reverse polarity protection:
yes
Short circuit protection:
yes
Resistive load
Max. admissible switching capacity:
1.5 W
Max. admissible switching current:
150 mA
Max. admissible switching voltage:
36 V
Inductive load - L < 100 mH
(DC voltage - without external safety circuit)
Max. admissible switching capacity:
1.5 VA
Max. admissible switching current:
40 mA
Max. admissible switching voltage:
36 V
Capacitive load - C < 20 µF
Max. admissible switching capacity:
1.5 VA
Max. admissible switching current:
1.5 A
Max. admissible switching voltage:
36 V
Insulation voltage:
signal contact - central electronic unit DC 500 V
signal contact - signal contact DC 500 V