TECHNICAL DATA
64
Flow Meter |
FC
01- CA
9 .4 Signal outputs
The signal outputs are physically isolated from each other as well as from the electronic
control unit FC01-CA .
9 .4 .1 Relay outputs R2
(SPDT)
Pin selection:
Signal name
Pin XAH
Limit Switch 1 / shield
1
Limit Switch 1 / N.O.
2
Limit Switch 1 / common
3
Limit Switch 1 / N.C.
4
Limit Switch 2 / shield
5
Limit Switch 2 / N.O.
6
Limit Switch 2 / common
7
Limit Switch 2 / N.C.
8
Resistive load
Max. admissible switching capacity:
50 W
Max. admissible switching current:
1 A
Max. admissible continuous current:
1 A
Max. admissible switching voltage:
50 V
Contact life at 1 A:
3 x 10
5
cycles
Inductive load - with safety circuit - AC voltage
Max. admissible switching capacity:
125 VA
Max. admissible switching current:
1.25 A
Max. admissible continuous current:
1.25 A
Max. admissible switching voltage:
100 V
Contact life cos
ϕ
= 0.5:
2.4 x 10
5
cycles
Insulation voltage:
signal contact - central electronic unit DC 500 V
signal contact - signal contact DC 500 V