28
Flow Meter |
FC
01- CA
INSTALLATION
XAH - Limit switch signal outputs - transistor outputs NPN, freely connectable as
emitter (-) and collector (+) have been brought out separately .
Connection by 8 pole connector; max. 1.5 mm
2
; LifYCY 4 x 2 x 0.2 mm
2
cable recommended
Pin No.
Signal name
Function
1
/ERROR E
summarized error indication - emitter terminal
2
/ERROR C
summarized error indication - collector terminal
3
/BUSY/PULSE E
availability signal or frequency output -
emitter terminal
4
/BUSY/PULSE C
availability signal or frequency output -
collector terminal
5
LIM2 E
limit value 2 - emitter terminal
6
LIM2 C
limit value 2 - collector terminal
7
LIM1 E
limit value 1 - emitter terminal
8
LIM1 C
limit value 1 - collector terminal
XSK - Connection of calorimetric monitoring heads type CS_x
Pre-sized connecting cable Do+Ka type 15 or Do+Ka type 18 with plug-in screw terminal strip (see
2.1.8)
(XAS - secondary current supply)
Only for connection of cable shield (not released for user)
Pin No.
Signal name
Function
3
SGND
shield ground