5.5 Extension cable connection
An optional extension cable (A80312) can be used
to extend the distance from the transducer to the unit
by up to 4 m (13.1 ft).
1. Existing cable.
2. Extension cable (connected to the vessel’s
power supply and to the existing cable.
3. Isolated power supply wires on existing
transducer cable.
Note:
• Only 1 extension cable should be used per
installation.
• The length of the power supply wires on the
extension cable is 2 m (6.6 ft).
Maximum transducer cable length
The maximum cable length from the transducer to
the unit is shown below.
CPT-DV
8 m (26.2 ft.)
— 4 m (13.1 ft.)
supplied cable + 4 m (13.1 ft.)
extension cable
CPT-DVS
10 m (32.8 ft.)
— 6 m (19.7
ft.) supplied cable + 4 m (13.1
ft.) extension cable
Note:
Extending the transducer cable further than
the maximum stated distance will cause poor
performance.
Cables and connections
41
Summary of Contents for E70290
Page 2: ......
Page 4: ......
Page 12: ...12 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 18: ...18 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 34: ...34 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 42: ...42 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 108: ...108 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 112: ...112 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 122: ...122 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 126: ...126 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 132: ...132 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 135: ......