Alarms menu
The Alarms available are dependent on the display variant.
Alarm
Applicable displays
Description
Options
Deep Water
Arrival
•
DV
•
DVS
•
Pro
When set to On, an alarm is
triggered when the depth reaches
the value speciied in the
Deep
Limit
setting. This option is only
available when current depth data
is available.
Note:
The
Deep limit
cannot
be set to a value less than the
Shallow Limit
.
Deep:
• Off (default)
• On
Deep Limit:
• 2 ft (or equivalent units) to the
maximum of the transducer
range
Shallow
Water Arrival
•
DV
•
DVS
•
Pro
When set to On, an alarm is
triggered when the depth reaches
the value speciied in the
Shallow
Limit
setting. This option is only
available when current depth data
is available.
Note:
The
Shallow Limit
cannot be set
to a depth greater than the
Deep
Limit
.
Shallow:
• Off (default)
• On
Shallow Limit:
• 2 ft (or equivalent units) to the
maximum of the transducer
range
Fish
•
DVS
•
Pro
If the Fish alarm and ish depth
limits alarm are set to On, a warning
sound is triggered if any target
meets the sensitivity level and is
within the Shallow Fish Limit and
Deep Fish Limit that you specify.
The following items are available in
the sub-menu:
•
Fish
— Switches ish alarm On
and Off.
•
Fish Sensitivity
— If the Fish
alarm is set to On, an alarm is
triggered when the ish return
strength reaches the sensitivity
that you specify.
•
Fish Depth Limits
— Switches
depth limits On and Off.
•
Shallow Fish Limit
— Speciies
the lower value for the Fish
Alarm Depth Limit.
•
Deep Fish Limit
— Speciies the
upper value for the Fish Alarm
Depth Limit.
Fish
• Off (default)
• On
Fish Sensitivity
• 1 to 10
Fish Depth Limits
• On
• Off (default)
Shallow Fish Limit
• 2 ft (or equivalent units) to the
maximum of the transducer
range
Deep Fish Limit
• 2 ft (or equivalent units) to the
maximum of the transducer
range
Water
Temperature
•
DVS
•
Pro
When set to On, an alarm and
pop-up message is triggered when
the water temperature is equal to or
lower than the Lower Temp Limit, or
equal to or greater than the Upper
Temp Limit.
Water Temperature
• Off (default)
• On
Lower Temp Limit
• 60 degrees fahrenheit (or
equivalent units)
• –09.9 to +99.7 degrees
fahrenheit (or equivalent units)
Upper Temp Limit
Tools & Settings
103
Summary of Contents for E70290
Page 2: ......
Page 4: ......
Page 12: ...12 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 18: ...18 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 34: ...34 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 42: ...42 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 108: ...108 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 112: ...112 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 122: ...122 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 126: ...126 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 132: ...132 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Page 135: ......