45
Winterizing the Unit
If you will not be using your Flavor Burst
®
system during the off-season or other extended
periods of time, you should winterize the FB
80D system as a precautionary practice to
avoid damage or undesirable syrup build-up in
the unit.
NOTE:
YOU DO NOT NEED TO USE
ANTIFREEZE SOLUTION IN THIS SYSTEM
WHEN WINTERIZING THE UNIT.
1. Perform the Clean-In-Place procedure as
instructed, except do not reconnect the
Syrup Bag Adapters or the Connectors to
the syrup bags.
2. Remove each syrup bag from its tray and
store as directed on the label. (See
Figure 110.)
26190
Figure 110
3. Empty all the sanitizer solution from the
Sanitizer Tank. (See Figure 111.)
26246
Figure 111
4. Repeat Steps 15-18 of the Clean-In-Place
Procedure without sanitizer solution in the
tank until the syrup lines are empty of
sanitizer solution. Then perform Steps 20
and 21 (skip Step 19)
.
5. With a container under the Injector Head,
press the WATER / SYRUP FLUSH key
until the sanitizer solution is removed from
the sanitizer line. (See Figure 112.)
26250
Figure 112
6. Clean the Injector Assembly and other parts
for off-season storage according to DAILY
CLOSING PROCEDURES and
SCHEDULED MAINTENANCE sections.
(See Figure 113.)
26010
Figure 113
NOTE:
DO NOT OPEN OR DISASSEMBLE
THE DRIVE ASSEMBLY GEAR BOX.
7. When opening next season, be sure to
perform the Clean-In-Place procedure again
to sanitize all pumps before recharging the
system with syrups.
Summary of Contents for FB 80D Series
Page 5: ...4 General System Overview 13 2 1 3 5 6 15 14 10 8 11 12 9 7 17 16 4 26000 Figure 1...
Page 7: ...6 Outer Cabinet 3 1 2 12 10 7 13 4 5 9 8 6 11 26001 Figure 2...
Page 9: ...8 Inner Cabinet 26002 15 11 13 16 14 11 12 1 9 2 6 6 11 18 19 16 4 5 3 4 17 11 8 10 7 Figure 3...
Page 20: ...19...
Page 24: ...23...
Page 32: ...31...
Page 62: ...61...
Page 72: ...71...