![Flavor Burst FB 80D Series Manual Download Page 25](http://html1.mh-extra.com/html/flavor-burst/fb-80d-series/fb-80d-series_manual_2303436025.webp)
24
NOTE:
YOUR HANDS SHOULD BE CLEANED
AND SANITIZED BEFORE YOU PERFORM
THE FOLLOWING PROCEDURES.
NOTE:
THE FOLLOWING PROCEDURES
REQUIRE APPROVED, SERVICEABLE AND
SANITIZED TOOLS AND BRUSHES.
CONTACT YOUR LOCAL DISTRIBUTOR FOR
RECOMMENDED SUPPLIES.
NOTE:
USE AN APPROVED CLEANER AND
SANITIZER FOR THE FOLLOWING
PROCEDURES. REFER TO
MANUFACTURER’S INSTRUCTIONS FOR
PROPER PREPARATIONS OF THESE
CLEANING AGENTS.
NOTE:
INSPECT ALL WEAR ITEMS AND
REPLACE IF NECESSARY.
Removing the Injector System
Follow these instructions to remove the Injector
System from the freezer during closing.
1. With a container under the dispensing
spout, press the WATER / SYRUP FLUSH
key on the Keypad to purge any remaining
product from the Injector Head. (See
Figure 22.)
26250
Figure 22
2. Rotate the 9-Tube Assembly coupler until it
unlocks and is able to slide out of the
Injector Head syrup line opening. (See
Figure 23.)
26050
Figure 23
3. Hang the 9-Tube Assembly on the
Accessory Hanging Bracket. (See
Figure 24.)
26184
Figure 24
4. Rotate the Injector Head locking collar until
it unlocks from the Spout Adapter and
remove the Injector Head from the Adapter.
(See Figure 25.)
26051
Figure 25
DAILY CLOSING PROCEDURES
Summary of Contents for FB 80D Series
Page 5: ...4 General System Overview 13 2 1 3 5 6 15 14 10 8 11 12 9 7 17 16 4 26000 Figure 1...
Page 7: ...6 Outer Cabinet 3 1 2 12 10 7 13 4 5 9 8 6 11 26001 Figure 2...
Page 9: ...8 Inner Cabinet 26002 15 11 13 16 14 11 12 1 9 2 6 6 11 18 19 16 4 5 3 4 17 11 8 10 7 Figure 3...
Page 20: ...19...
Page 24: ...23...
Page 32: ...31...
Page 62: ...61...
Page 72: ...71...