12
2.2 Equipment Calibration
The equipment includes the following leveling and calibration operations:
Manual mode: Z-axis calibration, X,Y-axis calibration, expert mode calibration.
Auxiliary (Assist) mode: Sensor calibration, automatic leveling.
The equipment has been leveled and calibrated before leaving the factory, so it is
generally unnecessary to calibrate again. However, the leveling plane may be
damaged due to the vibration generated during transportation. It is recommended
to perform a Z-axis calibration before printing.
Please proceed in the following order:
1. Click the -[Level and Calibibration] on the touch screen;
2. Select manual mode for Z-axis calibration;
3. Perform Z-axis calibration and operate following the screen prompts.
Before the equipment leaves the factory, the extruder sensor
calibration has been set, so it is unnecessary to operate again.
ATTENTION