P2.1
HEAT CURVE
STEEPNESS
Heating curve steepness indicates
what temperature is required
for the heating bodies by a
determined outdoor temperature.
See chapter Heating curve.
0,1 ÷ 2,6
0,5 - floor
1,0 - radiators
P2.2
PARALLEL
SHIFT OF
HEATING
CURVE
Setting of parallel shift of heating
curve or calculated stand-pipe
temperature.
Use this setting to eliminate
deviation between actual and
required room temperature.
-15 ÷ 15 °C
0
P2.3
DURATION
OF BOOST
HEATING
Duration of boosted room
temperature by changeover from
night to day heating period.
0 ÷ 200 min 0
P2.4
ROOM
TEMP. IN-
CREASE BY
BOOST
HEATING
Boost room temperature increase
by changeover from night to day
heating period.
0 ÷ 8 °C
3