85
Installation manual
EN
CONTROLLER INSTALLATION
The controller must be installed in an outdoor and dry area. Avoid immediate proximity
of strong electromagnetic field sources. The controller can be installed either directly
onto a wall or onto an installation batten.
INSTALLATION ONTO A WALL
The W.. controller is usually installed in the boiler room.
The installation onto a wall is conducted as follows:
1. In the installation spot, drill 2 holes with the diameter of 6 mm and depth of
approximately 35 mm. The centres of the holes must be vertically 120 mm apart.
Place wall inserts into the holes. Screw the screw into the upper wall insert so that the
screw head is approximately 4 mm away from the wall.
2. Hang the controller onto the upper screw.
3. Insert the bottom screw and screw it in.