2. Compressor operates, but pressure does not increase
in tank (or increases too slowly):
a) The cap on the intake tube has not been removed and
replaced by the intake filter (fig. 2).
b) Intake filter is clogged. Replace.
c) Leaks in fittings, tubes or pneumatic equipment. Check
with soapy water. Pressure drop is not to exceed 1 bar
per hour.
d) Clogged non-return valve or pressure pipe. Clean or
replace the parts (fig. 10).
e) Air leaks from the unloader valve when the compressor
is operating. Check or replace the unloader valve (fig. 9).
f) Defective valve plate. Contact your JUN-AIR distributor.
3. Loud noise from compressor:
a) Most likely broken suspension spring(s). Replace the
spring and ensure that motor position is horizontal.
b) The internal pressure pipe touches the rib cover or
the cylinder block. Dismount the rib cover and bend the
pressure pipe away.
4. Compressor gets very hot and/or uses a lot of oil:
a) Incorrect oil level. The level must appear in the oil level
glass (fig. 5).
b) Wrong oil has been filled in the compressor. Use only
SJ-27 synthetic lubricant which has the correct viscosity.
c) Leaks. See point 2c.
d) Clogged intake filter. See point 2b.
e) Too high ambient temperature. Do not install the
compressor in a cabinet unless adequately ventilated
(fig. 1).
f) The compressor is overloaded (i.e. it is operating more
than 50% of the operation time). Contact your JUN-AIR
distributor.
5. Compressor starts when no air is being used:
a) Leaks. See point 2c.
6. Compressor starts and stops more frequently than
usual:
a) Condensate in the air receiver. Empty the receiver by
means of the drain cock (fig. 6).
b) Leaks. See point 2c.
Pressure vessel
Pressure tested at:
4-25 liter:
40-50 liter:
Directions for use
Application
Receiver for compressed air.
Receiver specifications See name plate.
Installation
Tubes, etc. must be made of
suitable materials.
Placement
Observe the working temperature
of the receiver.
Ensure that sufficient room for
inspection/maintenance is
available in a horizontal position.
The receiver must be kept in a
horizontal position.
Corrosion protection
The surface treatment must be
maintained as required.
Internal inspection at least every
5 years.
Drain moisture at least once a week.
Alternation/repair
No welding must be made on
pressurized parts.
Safety valve
Ensures that PS will not be exceeded.
Never adjust to a higher pressure
than PS.
The capacity of the valve must be
calculated in accordance
with the volume of air supplied by
the compressor.
(PS = Maximum working pressure
of the receiver)
Declaration of Conformity
NOTE: The declaration of conformity is only valid for units
operating at 230 V/50 Hz, 3x400 V/50 Hz, 12 V DC or
24 V DC.
The manufacturer, JUN-AIR International A/S, declares that the
products mentioned in this manual are in conformity with:
• 87/404/EEC - 90/488/EEC - 93/68/EEC Council Directive
relating to Simple Pressure Vessels
• 89/392/EEC - 91/368/EEC - 93/44/EEC - 93/68/EEC
Council Directive of Safety of Machinery
• 89/336/EEC Council Directive of Electric Magnetic
Compatibility
• 73/23/EEC Low-voltage Directive
Flemming Petersen
Quality Manager
24 bar
18.3 bar
Operating manual
GB
Summary of Contents for JUN-AIR 12 - 15
Page 2: ......
Page 4: ......
Page 33: ...33 Motor spare parts model 3 Motor spare parts model 3 0013001 0013101 Drawings Drawings...
Page 34: ...34 Motor spare parts model 6 Motor spare parts model 6 0015100 0015200 Drawings...
Page 35: ...35 Spare parts model 6 15 0015400 Spare parts model 3 4 6 4 0015300 Drawings...
Page 36: ...36 Spare parts model 6 25 0015450 Spare parts model 12 25 0019700 Drawings...
Page 37: ...37 Spare parts model 18 40 0200660 Spare parts model 12 40 0200650 Drawings...
Page 38: ...38 Spare parts model 24 40 0200670 Spare parts model 36 150 0016500 Drawings...
Page 39: ...39 Accessories 0991041 0015900 0991040 Drawings...
Page 40: ...40 Electrical drawing model 3 6070010 Drawings...
Page 41: ...41 Electrical drawing model 6 6070160 Drawings...
Page 42: ...42 Electrical drawing model 12 6070210 Drawings...
Page 43: ...43 Electrical drawing model 18 6070260 Drawings...
Page 44: ...44 Electrical drawing model 24 400V 50Hz 6070310 Drawings...
Page 45: ...45 Electrical drawing model 24 230V 50 60Hz 6070311 Drawings...
Page 46: ...46 Electrical drawing model 36 400V 50Hz 6070360 Drawings...
Page 47: ...47 Electrical drawing model 36 230V 50Hz 6070361 Drawings...
Page 48: ......
Page 50: ......
Page 51: ......